Evidence map›Paper›PMID 38952071›Full record

ArticleJournal of applied clinical medical physics2024

Total body irradiation: A transition from a Co-60 treatment unit to an IMRT lateral-field extended-SAD technique.

Anastasia Kolokotronis, Malik Brunet-Benkhoucha, Étienne Roussin, Julie St-Pierre, Eve-Lyne Marchand, Maryse Bernard

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anastasia KolokotronisDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.
Malik Brunet-BenkhouchaDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.
Étienne RoussinDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.
Julie St-PierreDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.
Eve-Lyne MarchandDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.
Maryse BernardDépartement de Radio-oncologie, CIUSSS de l'Est-de-L'Île-de-Montréal, Hôpital Maisonneuve-Rosemont, Montréal, Quebec, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this work was to detail our center's experience in transitioning from a Co-60 treatment technique to an intensity modulated radiation therapy (IMRT) based lateral-field extended source-to-axis distance (e-SAD) technique for total body irradiation (TBI). MATERIALS AND

methodsAn existing beam model in RayStation v.10A was validated for the use of e-SAD TBI treatments. Data were acquired with an Elekta Synergy linear accelerator (LINAC) at an extended source-to-surface distance of 365 cm with an 18 MV beam. Beam model validation measurements included percentage depth dose (PDD), profile data, surface dose, build-up region and transmission measurements. End-to-end testing was carried out using an anthropomorphic phantom. Treatments were performed in a supine position in a whole-body Vac-Lok at an e-SAD of 400 cm with a beam spoiler 10 cm from the couch. Planning was achieved using IMRT, where multi-leaf collimators were used to modulate the beam and shield the organs at risk. Beam's eye view projection images were used for in-room patient positioning and in-vivo dosimetry was performed for every treatment.

resultsThe percent difference between the measured and calculated PDD and profiles was less than 2% at all locations. Surface dose was 83.8% of the maximum dose with the beam spoiler at a 10 cm distance from the phantom. The largest percent difference between the treatment planning system (TPS) and measured data within the anthropomorphic phantom was approximately 2%. In-vivo dosimetry measurements yielded results within the 5% institutional threshold.

conclusionIn 2022, 17 patients were successfully treated using the new IMRT-based lateral-field e-SAD TBI technique. The resulting clinical plans respected the institutional standard. The commissioning process, as well as the treatment planning and delivery aspects were described in this work with the intention of supporting other clinics in implementing this treatment method.

Indexed as

Cobalt RadioisotopesOrgans at RiskParticle AcceleratorsPhantoms, ImagingRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedWhole-Body IrradiationHumansNeoplasmsCobalt-60Cobalt Radioisotopesextended‐SSD IMRTTBI commissioningTBI treatment planningtotal body irradiation (TBI)

Identifiers

PMID38952071
PMCPMC11492311

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.