Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparison of Short-Term Results of Total Hip Arthroplasty with Polarstem by Dorr Type.Indian journal of orthopaedics · 2025Article
Corrections and comments
- Erratum issued
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn recent years, the use of tapered-wedge short stems has increased due to their ability to preserve bones and tendons. Surgical techniques occasionally result in a varus position of the stem, which is particularly pronounced in short stems. Although the varus position is not clinically problematic, there are reports of an increased incidence of stress shielding and cortical hypertrophy. Thus, we evaluated and examined the acceptable range of varus angles using finite element analysis.
methodsPatients diagnosed with osteoarthritis of the hip joint who had undergone arthroplasty were selected and classified into three types [champagne-flute (type A), intermediate (type B), and stovepipe (type C)]. Finite element analysis was performed using Mechanical Finder. The model was created using a Taperloc microplasty stem with the varus angle increased by 1° from 0° to 5° from the bone axis and classified into seven zones based on Gruen's zone classification under loading conditions in a one-leg standing position. The volume of interest was set, the mean equivalent stress for each zone was calculated.
resultsA significant decrease in stress was observed in zone 2, and increased stress was observed in zones 3 and 4, suggesting the emergence of a distal periosteal reaction, similar to the results of previous studies. In zone 2, there was a significant decrease in stress in all groups at a varus angle ≥ 3°. In zone 3, stress increased from ≥ 3° in type B and ≥ 4° in type C. In zone 4, there was a significant increase in stress at varus angles of ≥ 2° in types A and B and at ≥ 3° in type C.
conclusionIn zone 2, the varus angle at which stress shielding above Engh classification grade 3 may appear is expected to be ≥ 3°. Distal cortical hypertrophy may appear in zones 3 and 4; the narrower the medullary cavity shape, the smaller the allowable angle of internal recession, and the wider the medullary cavity shape, the wider the allowable range. Long-term follow-up is required in patients with varus angles > 3°.