Evidence map›Paper›PMID 38951831›Full record

ArticleBMC medical informatics and decision making2024

Real-time non-invasive hemoglobin prediction using deep learning-enabled smartphone imaging.

Yuwen Chen, Xiaoyan Hu, Yiziting Zhu, Xiang Liu, Bin Yi

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuwen Chen *Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, 400714, China.
Xiaoyan Hu *Department of Anaesthesiology, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China.
Yiziting Zhu *Department of Anaesthesiology, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China.
Xiang LiuDepartment of Anaesthesiology, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China.
Bin YiDepartment of Anaesthesiology, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China. yibin1974@163.com.

Funding

Chongqing Talents Project CQYC202103080National Key Research and Development Program of China 2018YFC0116702National Natural Science Foundation of China 62371438National Natural Science Foundation of China 82070630Natural Science Foundation of Chongqing (Key Project) CSTB2023NSCQ-ZDJ0005Natural Science Foundation of Chongqing Municipality CSTB2022NSCQ-MSX0894
6 · The paper itself

Abstract

backgroundAccurate measurement of hemoglobin concentration is essential for various medical scenarios, including preoperative evaluations and determining blood loss. Traditional invasive methods are inconvenient and not suitable for rapid, point-of-care testing. Moreover, current models, due to their complex parameters, are not well-suited for mobile medical settings, which limits the ability to conduct frequent and rapid testing. This study aims to introduce a novel, compact, and efficient system that leverages deep learning and smartphone technology to accurately estimate hemoglobin levels, thereby facilitating rapid and accessible medical assessments.

methodsThe study employed a smartphone application to capture images of the eye, which were subsequently analyzed by a deep neural network trained on data from invasive blood test data. Specifically, the EGE-Unet model was utilized for eyelid segmentation, while the DHA(C3AE) model was employed for hemoglobin level prediction. The performance of the EGE-Unet was evaluated using statistical metrics including mean intersection over union (MIOU), F1 Score, accuracy, specificity, and sensitivity. The DHA(C3AE) model's performance was assessed using mean absolute error (MAE), mean-square error (MSE), root mean square error (RMSE), and R^2.

resultsThe EGE-Unet model demonstrated robust performance in eyelid segmentation, achieving an MIOU of 0.78, an F1 Score of 0.87, an accuracy of 0.97, a specificity of 0.98, and a sensitivity of 0.86. The DHA(C3AE) model for hemoglobin level prediction yielded promising outcomes with an MAE of 1.34, an MSE of 2.85, an RMSE of 1.69, and an R^2 of 0.34. The overall size of the model is modest at 1.08 M, with a computational complexity of 0.12 FLOPs (G).

conclusionsThis system presents a groundbreaking approach that eliminates the need for supplementary devices, providing a cost-effective, swift, and accurate method for healthcare professionals to enhance treatment planning and improve patient care in perioperative environments. The proposed system has the potential to enable frequent and rapid testing of hemoglobin levels, which can be particularly beneficial in mobile medical settings.

trial registrationThe clinical trial was registered on the Chinese Clinical Trial Registry (No. ChiCTR2100044138) on 20/02/2021.

Indexed as

Deep LearningHemoglobinsSmartphoneFemaleHumansMaleMiddle AgedMobile ApplicationsHemoglobinsAutomaticDeep learningHemoglobinNon-invasive predictionSmartphone

Identifiers

PMID38951831
PMCPMC11218390

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.