ArticleBMC medical informatics and decision making2024
Real-time non-invasive hemoglobin prediction using deep learning-enabled smartphone imaging.
Article in BMC medical informatics and decision making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Foundation model-based haemoglobin concentration estimation and anaemia risk assessment from retinal fundus images.Eye (London, England) · 2026Article
- Applications of Machine Learning in Noninvasive Anemia Diagnosis: A Systematic Review Based on Cross-Industry Standard Process for Data Mining.Health science reports · 2026Review
- Development and early feasibility testing of machine-learning algorithms to non-invasively assess hemoglobin levels.npj biomedical innovations · 2026Article
- Artificial intelligence in public health-challenges and opportunities.European journal of clinical nutrition · 2026Review
- Deep Learning Integration in Optical Microscopy: Advancements and Applications.Microscopy research and technique · 2026Review
- Physician Gestalt for Anemia Detection in the Emergency Department: A Prospective Study.The western journal of emergency medicine · 2026Observational
- Estimation of Total Hemoglobin (SpHb) from Facial Videos Using 3D Convolutional Neural Network-Based Regression.Biosensors · 2025Article
- Predicting individual hemoglobin abnormalities using longitudinal data in clinical practice.BMC medical informatics and decision making · 2025Article
- Clinical Bedside Benchmarking Test for Measuring the Total Hemoglobin Concentration.Healthcare (Basel, Switzerland) · 2025Article
- Article
- Radiomic identification of anemia features in monochromatic conjunctiva photographs in school-age children.Biophotonics discovery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundAccurate measurement of hemoglobin concentration is essential for various medical scenarios, including preoperative evaluations and determining blood loss. Traditional invasive methods are inconvenient and not suitable for rapid, point-of-care testing. Moreover, current models, due to their complex parameters, are not well-suited for mobile medical settings, which limits the ability to conduct frequent and rapid testing. This study aims to introduce a novel, compact, and efficient system that leverages deep learning and smartphone technology to accurately estimate hemoglobin levels, thereby facilitating rapid and accessible medical assessments.
methodsThe study employed a smartphone application to capture images of the eye, which were subsequently analyzed by a deep neural network trained on data from invasive blood test data. Specifically, the EGE-Unet model was utilized for eyelid segmentation, while the DHA(C3AE) model was employed for hemoglobin level prediction. The performance of the EGE-Unet was evaluated using statistical metrics including mean intersection over union (MIOU), F1 Score, accuracy, specificity, and sensitivity. The DHA(C3AE) model's performance was assessed using mean absolute error (MAE), mean-square error (MSE), root mean square error (RMSE), and R^2.
resultsThe EGE-Unet model demonstrated robust performance in eyelid segmentation, achieving an MIOU of 0.78, an F1 Score of 0.87, an accuracy of 0.97, a specificity of 0.98, and a sensitivity of 0.86. The DHA(C3AE) model for hemoglobin level prediction yielded promising outcomes with an MAE of 1.34, an MSE of 2.85, an RMSE of 1.69, and an R^2 of 0.34. The overall size of the model is modest at 1.08 M, with a computational complexity of 0.12 FLOPs (G).
conclusionsThis system presents a groundbreaking approach that eliminates the need for supplementary devices, providing a cost-effective, swift, and accurate method for healthcare professionals to enhance treatment planning and improve patient care in perioperative environments. The proposed system has the potential to enable frequent and rapid testing of hemoglobin levels, which can be particularly beneficial in mobile medical settings.
trial registrationThe clinical trial was registered on the Chinese Clinical Trial Registry (No. ChiCTR2100044138) on 20/02/2021.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.