ArticleScientific reports2024
Reduction in lower urinary tract mucosal microtrauma as an effect of reducing eyelet sizes of intermittent urinary catheters.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The Micro-hole Zone Technology as a new era in urinary drainage: a narrative review from bench to bedside.BMC urology · 2026Review
- Unveiling the Potential of Fish Swim Bladder-Derived Biomaterials in Urological Care.Advances in urology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intermittent catheterization (IC) utilizing conventional eyelets catheters (CECs) for bladder drainage has long been the standard of care. However, when the tissue of the lower urinary tract comes in close proximity to the eyelets, mucosal suction often occurs, resulting in microtrauma. This study investigates the impact of replacing conventional eyelets with a drainage zone featuring multiple micro-holes, distributing pressure over a larger area. Lower pressures limit the suction of surrounding tissue into these micro-holes, significantly reducing tissue microtrauma. Using an ex vivo model replicating the intra-abdominal pressure conditions of the bladder, the intra-catheter pressure was measured during drainage. When mucosal suction occurred, intra-catheter images were recorded. Subsequently affected tissue samples were investigated histologically. The negative pressure peaks caused by mucosal suction were found to be very high for the CECs, leading to exfoliation of the bladder urothelium and breakage of the urothelial barrier. However, a micro-hole zone catheter (MHZC) with a multi-eyelet drainage zone showed significantly lower pressure peaks, with over 4 times lower peak intensity, thus inducing far less extensive microtraumas. Limiting or even eliminating mucosal suction and resulting tissue microtrauma may contribute to safer catheterizations in vivo and increased patient comfort and compliance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.