Consistency analysis of two fingertip capillary blood sampling methods for complete blood count.

Xie Hongxiang, Lv Shiyu, Zhang Yanying, Xu Wanju, Wang Sumei

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xie Hongxiang *Laboratory Medicine Center, Department of Clinical Laboratory, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, No. 158 Shangtang Road, Hangzhou, 310014, Zhejiang, People's Republic of China.
Lv Shiyu *Department of Clinical Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, 16766 Jingshi Road, Jinan, 250014, Shandong, People's Republic of China.
Zhang YanyingDepartment of Clinical Laboratory, Zaozhuang Chest Hospital, Zaozhuang Tumor Hospital, Zaozhuang, Shandong, People's Republic of China.
Xu WanjuDepartment of Clinical Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, 16766 Jingshi Road, Jinan, 250014, Shandong, People's Republic of China. 15098908396@163.com.
Wang SumeiLaboratory Medicine Center, Department of Clinical Laboratory, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, No. 158 Shangtang Road, Hangzhou, 310014, Zhejiang, People's Republic of China. wsm1979lab@126.com.

Funding

Natural Science Foundation of Shandong Province ZR2020MH116
6 · The paper itself

Abstract

This study was performed to analyze fingertip capillary blood sampling in pediatric patients using microcapillary blood collection tubes and microhematocrit tubes and to compare the blood cell analysis results obtained via these two blood collection methods. Finger capillary blood was collected from 110 outpatients using microcapillary blood collection tubes and microhematocrit tubes and complete blood count analysis was performed with a Sysmex XS-900i hematology analyzer and manual microscopy for blood cell morphology. Paired data was evaluated for agreement and bias using the microhematocrit samples as the reference group and the samples from the microcapillary blood collection tubes as the observation group. The two blood collection methods demonstrated good agreement for measuring red blood cell (RBC) parameters (i.e., RBC, Hb, Hct, MCV, MCH and MCHC), wherein the relative bias was > allowable total error (TEa) in 0.91%, 1.82%, 11.82%, 1.82%, 0.91% and 8.18% of the parameter measures, respectively. According to industry requirements, the proportion of samples meeting the acceptable bias level should be > 80%. Additionally, the estimated biases at each medical decision level were within clinically acceptable levels for RBC, Hb, Hct, and MCV. However, the proportion of WBC and PLT counts with relative bias > TEa was 25.45% and 35.45%, respectively. Furthermore, the relative bias of the WBC count at the medical decision level of 0.5 × 10

Indexed as

Blood Specimen CollectionAdolescentBlood Cell CountCapillariesChildChild, PreschoolFemaleFingersHumansInfantLeukocyte CountMaleBlood collection tubesCapillary bloodComplete blood countMicrohematocrit tubes

Identifiers

PMID38951565
PMCPMC11217387

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.