Evidence map›Paper›PMID 38951283›Full record

ArticleJournal of robotic surgery2024

Ideal suturing technique for robot-assisted microsurgical anastomoses.

Kai J Wessel, Isa Wendenburg, Charalampos Varnava, Sascha Wellenbrock, Alexander Dermietzel, Mirkka Hiort, David Kampshoff, Philipp Wiebringhaus, Tobias Hirsch, Maximilian Kueckelhaus

Abstract read
In one paragraph

Article in Journal of robotic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Translational andrology and urology · 2026
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kai J Wessel *Department of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Isa Wendenburg *Department of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Charalampos VarnavaDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Sascha WellenbrockDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Alexander DermietzelDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Mirkka HiortDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
David KampshoffDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Philipp WiebringhausDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Tobias HirschDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany.
Maximilian KueckelhausDepartment of Plastic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48157, Muenster, Germany. maximilian.kueckelhaus@ukmuenster.de.

Funding

Deutsche Forschungsgemeinschaft 493624047REACT-EU EFRE-0802073
6 · The paper itself

Abstract

The development of novel robotic devices specifically designed for open microsurgery leads to increasing applications in reconstructive procedures. While initial studies revealed improved precision and surgical ergonomics upon robotic assistance, surgical time was consistently observed to be increased. This study compares two robotic suturing techniques using the Symani Surgical System and RoboticScope in a preclinical setting, to further leverage the benefits of novel robotic devices in microsurgery. Six experienced microsurgeons performed three microvascular anastomoses with a "steady-thread" suturing technique and a "switch-thread" technique on 1.0-mm-diameter artificial silicone vessels. Time for anastomosis and participant's satisfaction with the techniques and robotic setup were recorded. Anastomosis quality and microsurgical skills were assessed using the Anastomosis Lapse Index and Structured Assessment of Microsurgery Skills. Lastly, technical error messages and thread ruptures were quantified. Knot tying was significantly faster and evaluated significantly better by participants using the steady-thread technique (4.11 ± 0.85 vs. 6.40 ± 1.83 min per anastomosis). Moreover, microsurgical skills were rated significantly better using this technique, while both techniques consistently led to high levels of anastomosis quality (2.61 ± 1.21 vs. 3.0 ± 1.29 errors per anastomosis). In contrast, the switch-thread technique was associated with more technical error messages in total (14 vs. 12) and twice as many unintended thread ruptures per anastomosis (1.0 ± 0.88 vs. 0.5 ± 0.69). This study provides evidence for the enhanced performance of a steady-thread suturing technique, which is suggested to be applied upon robot-assisted microsurgical procedures for optimized efficiency.

Indexed as

Anastomosis, SurgicalMicrosurgeryRobotic Surgical ProceduresSuture TechniquesClinical CompetenceHumansOperative TimeAnastomosisKnotMicrosurgeryRoboticsRoboticScopeSutureSymani

Identifiers

PMID38951283
PMCPMC11217096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.