ArticleIndian pacing and electrophysiology journal
Longitudinal reduction in fluoroscopy with continued use of 3-dimensional electroanatomic mapping systems in catheter ablation of supraventricular tachycardia - then and now.
Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Zero-fluoroscopy versus fluoroscopy-guided catheter ablation in ventricular arrhythmia: A systematic review and meta-analysis.Narra J · 2025Pooled it
- Supraventricular Tachycardia Ablation in the Elderly-Characteristics and Outcomes.Journal of arrhythmia · 2026Article
- Use of 3D electroanatomic mapping systems allows us to see the past and predict the future of SVT ablation.Indian pacing and electrophysiology journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCatheter ablation is a first-line treatment for symptomatic, recurrent supraventricular tachycardia (SVT). This study aims to demonstrate if 3D-electroanatomic mapping (EAM) during SVT ablation reduces fluoroscopy time (FT) and determine if further reductions in FT are observed longitudinally.
methodsAll cases of SVT ablation between May 2011-May 2022 at a single tertiary centre were prospectively recruited. FT between the cohorts with and without EAM were compared. Within the EAM subset, the trend of FT across the years was analysed.
resultsThere were 1758 cases included, 563 without EAM, 1195 with EAM. EAM was associated with a longer procedure time (mean + 8.8 min, p = 0.001), but with mean reductions in FT and dose area product (DAP) by 19.6 min and 18 621 mGy*cm2 respectively (p < 0.001). There was comparable efficacy without any increase in complication rates. Over time (2011-2022), further reduction in FT of 0.9 min year on year was observed (p = 0.001). Between 2011 and 2017, there was a significant reduction in FT of 1.1 min year on year (p = 0.019), which was not observed from 2017 onwards (p = 0.061). The greatest reduction in FT was after the first year of adoption.
conclusionEAM in SVT ablation reduces fluoroscopy use. FT was initially observed to reduce further over time before plateauing, likely due to increased operator experience. While there is increased interest in zero fluoroscopy SVT ablation, complementary use of fluoroscopy may still be necessary in complex cases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials