Development and evaluation of a candidate reference measurement procedure for detecting 17α-hydroxyprogesterone in dried blood spots using isotope dilution liquid chromatography tandem mass spectrometry.

Ziyun He, Haibing Dai, Jian Shen, Yanjie Huang, Jinsong Liu, Renqing Yan, Feng Zhang, Shengkai Yan

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Interpol review of forensic drug chemistry, 2022-2025.Forensic science international. Synergy · 2026
    Review
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ziyun He *Department of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China.ORCID http://orcid.org/0000-0001-9787-8781
Haibing Dai *Department of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China.
Jian ShenGuangzhou Fenghua Biotech Co., Ltd., Guangzhou, 510730, China.
Yanjie HuangGuangdong Provincial Institute of Metrology, South China National Centre of Metrology, Guangzhou, 510405, China.
Jinsong LiuDepartment of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China.
Renqing YanDepartment of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China.
Feng ZhangDepartment of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China.
Shengkai YanDepartment of Laboratory Medicine, Affiliated Hospital of Zunyi Medical University, Zunyi, 563003, China. yanshengkai@sina.com.

Funding

National Natural Science Foundation of China 82070916Zunyi Science and Technology Planning Project Zun Shi Ke He HZ [2021] No. 185
6 · The paper itself

Abstract

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.

Indexed as

17-alpha-HydroxyprogesteroneDried Blood Spot TestingTandem Mass SpectrometryAdrenal Hyperplasia, CongenitalChromatography, LiquidFemaleHumansIndicator Dilution TechniquesInfant, NewbornLimit of DetectionNeonatal ScreeningReference StandardsReference ValuesReproducibility of Results17-alpha-Hydroxyprogesterone17α-HydroxyprogesteroneCongenital adrenal hyperplasiaDried blood spotsLiquid chromatography tandem mass spectrometryNewborn screening

Identifiers

PMID38949681
PMCPMC11294408

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.