Evidence map›Paper›PMID 38948075›Full record

ArticleJPRAS open2024

Tissue perfusion in DIEP flaps using Indocyanine Green Fluorescence Angiography, Hyperspectral imaging, and Thermal imaging.

Simone F Kleiss, Marlies Michi, Simone N Schuurman, Jean-Paul P M de Vries, Paul M N Werker, Steven J de Jongh

Abstract read
In one paragraph

Article in JPRAS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Clinical Value of Transcutaneous PCOJournal of clinical medicine · 2025
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Simone F KleissDepartment of Surgery, Division of Vascular Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Marlies MichiDepartment of Plastic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Simone N SchuurmanDepartment of Surgery, Division of Vascular Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Jean-Paul P M de VriesDepartment of Surgery, Division of Vascular Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Paul M N WerkerDepartment of Plastic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Steven J de JonghDepartment of Plastic Surgery, University Medical Center Groningen, Groningen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Flap necrosis continues to occur in skin free flap autologous breast reconstruction. Therefore, we investigated the benefits of indocyanine green angiography (ICGA) using quantitative parameters for the objective, perioperative evaluation of flap perfusion. In addition, we investigated the feasibility of hyperspectral (HSI) and thermal imaging (TI) for postoperative flap monitoring. A single-center, prospective observational study was performed on 15 patients who underwent deep inferior epigastric perforator (DIEP) flap breast reconstruction (n=21). DIEP-flap perfusion was evaluated using ICGA, HSI, and TI using a standardized imaging protocol. The ICGA perfusion curves and derived parameters, HSI extracted oxyhemoglobin (oxyHb) and deoxyhemoglobin (deoxyHb) values, and flap temperatures from TI were analyzed and correlated to the clinical outcomes. Post-hoc quantitative analysis of intraoperatively collected data of ICGA application accurately distinguished between adequately and insufficiently perfused DIEP flaps. ICG perfusion curves identified the lack of arterial inflow (n=2) and occlusion of the venous outflow (n=1). In addition, a postoperatively detected partial flap epidermolysis could have been predicted based on intraoperative quantitative ICGA data. During postoperative monitoring, HSI was used to identify impaired perfusion areas within the DIEP flap based on deoxyHb levels. The results of this study showed a limited added value of TI. Quantitative, post-hoc analysis of ICGA data produced objective and reproducible parameters that enabled the intraoperative detection of arterial and venous congested DIEP flaps. HSI appeared to be a promising technique for postoperative flap perfusion assessment. A diagnostic accuracy study is needed to investigate ICGA and HSI parameters in real-time and demonstrate their clinical benefit.

Indexed as

Breast reconstructionDIEP-flap reconstructionHyperspectral imagingIndocyanine Green AngiographyPerfusion imagingThermal imaging

Identifiers

PMID38948075
PMCPMC11214344

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.