Trial reportDrug design, development and therapy2024
Up-and-Down Determination of Different Crystalloid Coload Volumes on the ED 90 of Prophylactic Norepinephrine Infusion for Preventing Postspinal Anesthesia Hypotension During Cesarean Section.
Trial report in Drug design, development and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Vasopressor Regimens and Maternal Core Temperature During Cesarean Delivery: A Randomized, Double‑blind, Non‑inferiority Trial.Drug design, development and therapy · 2026Trial
- Up-and-down determination of prophylactic norepinephrine boluses combined with crystalloid co-load for preventing post-spinal anesthesia hypotension during cesarean section.BMC anesthesiology · 2025Trial
- Review
- A Commentary on "Effective Dose of Epidural Hydromorphone for Analgesia Following Caesarean Section in Using Modified Dixon Sequential Method" [Response to Letter].Journal of pain research · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Fluid loading improves hemodynamic stability and reduces the incidence rate of post-spinal anesthesia hypotension when prophylactic vasopressors are administered. We investigated the impact of different crystalloid coload volumes on the 90% effective dose (ED) of prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension in non-hypertensive patients undergoing cesarean section. Methods: Patients were randomly allocated to receive one of the different crystalloid coload volumes (0mL/kg [0mL/kg Group], 5mL kg [5mL/kg Group], and 10mL kg [10mL/kg Group]) in combination with prophylactic norepinephrine infusion immediately after the induction of spinal anesthesia. The prophylactic norepinephrine infusion doses were determined using the up-and-down sequential allocation methodology, with an initial dose of 0.025 μg/kg/min and a gradient of 0.005 μg/kg/min. The primary endpoint was the effective dose at which 90% (ED 90) of patients responded to prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension. Results: The estimated effective dose of norepinephrine infusion, at which 90% (ED 90) of patients responded, was found to be 0.084 (95% CI, 0.070 to 0.86), 0.074 (95% CI, 0.059 to 0.077), and 0.063 (95% CI, 0.053 to 0.064) μg/kg/min in the three groups, respectively. Conclusion: A crystalloid coload of 5 mL/kg or 10 mL/kg, as opposed to the groups receiving 0 mL/kg crystalloid coloads, resulted in a reduction of approximately 11.9% and 25.0%, respectively, in the ED90 of prophylactic norepinephrine infusion for preventing post-spinal anesthesia hypotension during cesarean section.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.