Evidence map›Paper›PMID 38946811›Full record

ArticleBiomedical engineering letters2024

Magnetic field control device for transplantation of corneal endothelial tissue with magnetic filaments.

Changyoung Yoo, Young-Il Kim, Ji-Myoung Jung, Hun Lee, Changmo Hwang, Seong-Wook Choi

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Changyoung YooInterdisciplinary Program in Biohealth-Machinery Convergence Engineering, Kangwon National University, Chuncheon-si, 24341 Republic of Korea.
Young-Il KimProgram of Mechanical and Biomedical Engineering, College of Engineering, Kangwon National University, Chuncheon-si, 24341 Republic of Korea.
Ji-Myoung JungInterdisciplinary Program in Biohealth-Machinery Convergence Engineering, Kangwon National University, Chuncheon-si, 24341 Republic of Korea.
Hun LeeDepartment of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505 Republic of Korea.
Changmo HwangDepartment of Biomedical Engineering, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505 Republic of Korea.
Seong-Wook ChoiInterdisciplinary Program in Biohealth-Machinery Convergence Engineering, Kangwon National University, Chuncheon-si, 24341 Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The corneal endothelial transplantation involves the transfer and attachment of a single-layered corneal endothelial tissue to the narrow space between the cornea and iris. Given the high risk of damage to the endothelial tissue and surrounding corneal tissues when using sharp instruments inserted externally to apply force during the process, the development of a device capable of transferring corneal endothelial tissue using a magnetic field became necessary. This study aims to develop a magnetic control device for transferring corneal endothelial tissue with attached magnetic particles to the transplant site, validate its appropriate transfer capabilities, and assess its applicability to corneal endothelial transplantation. For this purpose, a magnetic field-generating manipulation device equipped with four electromagnets controlled by a joystick and microcomputer was developed. Through simulated experiments, the strength of the magnetic field and the attraction force on the tissue were predicted, and the actual magnetic field strength was measured for validation. To measure the magnetic transfer force, experiments were conducted by towing corneal endothelial tissue fixed with 6 mg, 12 mg, and 18 mg plastic weights. Subsequently, the tissue's transfer speed was measured after applying continuous and pulsed magnetic fields. The results confirmed the feasibility of tissue transfer using the magnetic control device, and it was observed that pulsed magnetic fields led to faster transfer speeds and easier control compared to continuous magnetic fields. Exploratory animal experiments using rabbits were conducted to simulate real surgical conditions, confirming the feasibility of corneal endothelial tissue transfer and attachment.

Indexed as

Corneal endothelial transplantationDescemet’s stripping automated endothelial keratoplasty (DSAEK)Magnetic manipulation systemMicro-robots

Identifiers

PMID38946811
PMCPMC11208361

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials