ArticleArthroplasty (London, England)2024
No evidence of mid-flexion instability after robotic-assisted total knee arthroplasty as assessed by intraoperative pressure sensors.
Article in Arthroplasty (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Medial femoral condyle restoration technique in total knee arthroplasty.Arthroplasty (London, England) · 2026Article
- Editorial: Advances in artificial intelligence and robotics in joint arthroplasty.Arthroplasty (London, England) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeMid-flexion instability has been identified as a cause for dissatisfaction following total knee arthroplasty (TKA). Robotic-assisted surgery using the Mako robot only allows for assessment of stability at 10° and 90°. This study aimed to investigate any evidence of mid-flexion instability in Mako-assisted TKA.
methodsData from 72 TKA in 59 patients from 2018 to 2022 were collected. All patients underwent an RA (Mako, Stryker, Fort Lauderdale, FL, USA), single-radius design, cruciate-retaining TKA. Intraoperatively, medial, and lateral pressures were measured at 10°, 45° and 90° of flexion using a pressure sensor (Verasense, OrthoSensor, 59 Inc., Dania Beach, FL, USA). The knee was considered balanced if the difference in pressures between compartments was less than 15 pounds-force (lbf).
resultsThere was no significant difference between the pressures measured in the medial compartment at 10°, 45° and 90° of flexion (P = 0.696). A statistically significant difference was found between the pressures measured in the lateral compartment at 10°, 45° and 90° of flexion, with the 10° value being significantly higher (P < 0.001), but this did not exceed the threshold of 15 lbf. None of the patients had a pressure difference of more than 15 lbf when pressures at 45° were compared to that at 10° and 90°, medially or laterally.
conclusionThis study showed no evidence of mid-flexion instability in Mako-assisted TKA, using a single radius, cruciate-retaining prosthesis whilst maintaining the joint height. LEVEL OF EVIDENCE: Level III retrospective cohort study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.