Evidence map›Paper›PMID 38946008›Full record

ArticleEcho research and practice2024

Reproducibility of semi-quantitative assessment of aortic valve calcification and valve motion on echocardiography: a small-scale study.

D Balian, B Koethe, S Mohanty, Y Daaboul, S H Mahrokhian, J Frankel, J Li, A Kherlopian, B C Downey, B Wessler

Abstract read
In one paragraph

Article in Echo research and practice, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

D BalianTufts Medical Center, Boston, USA. Dikran.Balian@tufts.edu.
B KoetheTufts Medical Center, Boston, USA.
S MohantyTufts Medical Center, Boston, USA.
Y DaaboulTufts Medical Center, Boston, USA.
S H MahrokhianTufts Medical Center, Boston, USA.
J FrankelTufts Medical Center, Boston, USA.
J LiTufts Medical Center, Boston, USA.
A KherlopianTufts Medical Center, Boston, USA.
B C DowneyTufts Medical Center, Boston, USA.
B WesslerTufts Medical Center, Boston, USA.

Funding

Tufts Clinical and Translational Science Institute (Clinical Trial Design Labs Supplement)UM1TR004398 · NCATS · TUFTS UNIVERSITY BOSTON · PI Harry P. Selker · 2023 to 2026
$44.5M
Palliative Care for High-Risk TAVR Patients: The Impact of MultimorbidityK23AG055667 · NIA · TUFTS MEDICAL CENTER · PI WESSLER, BENJAMIN SETH · 2018 to 2022
$948k
NCATS NIH HHS UM1 TR004398NIA NIH HHS K23 AG055667
6 · The paper itself

Abstract

backgroundAortic stenosis (AS) is the most common degenerative valve disease in high income countries. While hemodynamic metrics are commonly used to assess severity of stenosis, they are impacted by loading conditions and stroke volume and are often discordant. Anatomic valve assessments such as aortic valve calcification (AVC) and valve motion (VM) during transthoracic echocardiography (TTE) can offer clues to disease severity. The reliability of these semi-quantitatively assessed anatomic imaging parameters is unknown.

methodsThis is a retrospective study of semi-quantitative assessment of AVC and valve VM on TTE. TTEs representing a range of AS severities were identified. The degree of calcification of the aortic valve and the degree of restricted VM were assessed in standard fashion. AVC scores and valve motion were assessed by readers with varied training levels blinded to the severity of AS. Correlation and inter-reader reliability between readers were assessed.

results420 assessments (210 each for AVC and VM) were collected for 35 TTEs. Correlation of AVC for imaging trainees (fellows and students, respectively), ranged from 0.49 (95% CI 0.18-0.70) to 0.62 (95% CI 0.36-0.79) and 0.58 (95% CI 0.30-0.76) to 0.54 (95% CI 0.25-0.74) for VM. Correlation of anatomic assessments between echocardiographer-assigned AVC grades was r = 0.76 (95% CI 0.57-0.87)). The correlation between echocardiographer-assigned assessment of VM was r = 0.73 (95% CI 0.53-0.86), p < 0.00001 for both. For echocardiographer AVC assessment, weighted kappa was 0.52 (0.32-0.72), valve motion weighted kappa was 0.60 (0.42-0.78).

conclusionThere was good inter-reader correlation between TTE-based semi-quantitative assessment of AVC and VM when assessed by board certified echocardiographers. There was modest inter-reader reliability of semi-quantitative assessments of AVC and VM between board certified echocardiographers. Inter-reader correlation and reliability between imaging trainees was lower. More reliable methods to assess TTE based anatomic assessments are needed in order to accurately track disease progression. CLINICAL TRIAL NUMBER: STUDY00003100.

Indexed as

Aortic stenosisEchocardiographyInter-reader ReliabilityReproducibilitySemi-quantitative

Identifiers

PMID38946008
PMCPMC11215824

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.