SynthesisThe Cochrane database of systematic reviews2024
Peripherally inserted central catheter design and material for reducing catheter failure and complications.
Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Peripherally inserted central catheter design and material for reducing catheter failure and complications.The Cochrane database of systematic reviews · 2024Pooled it
- Prevention of complications related to peripherally inserted central catheter insertion techniques in newborns: systematic review and network meta-analysis.Revista latino-americana de enfermagem · 2024Pooled it
- Pediatric home-based central venous access device dressings: Medical liquid adhesive versus standard care to reduce dressing disruption: The STICKY-kids RCT protocol.Journal of hospital medicine · 2026Trial
- Implementation contexts and strategies for alternative peripherally inserted central catheter material and design selection: A qualitative exploration using CFIR/ERIC approach.Journal of advanced nursing · 2025Trial
- Effects of two securement methods on peripherally inserted central catheter stability and skin integrity in very low birth weight infants: a retrospective study.Translational pediatrics · 2026Article
- Factors influencing nurses' knowledge on peripherally inserted central catheter care in Guizhou, China: A web-based cross-sectional study.Scientific reports · 2026Article
- Indications, Dwell Time, and Removal Reasons of Standardized Mid-Thigh Lower-Extremity PICCs in Adult ICU Patients: A Retrospective Cohort Study.Life (Basel, Switzerland) · 2026Article
- A critical use of peripherally inserted central catheters in the intensive care unit.Critical care science · 2026Article
- Comparison of time-segmented goal-directed teaching vs. traditional teaching for PICC among specialist nurse training: a randomized controlled trial.Frontiers in medicine · 2026Article
- Central venous catheter infections: building a causal model with expert domain knowledge to inform future clinical trials.Antimicrobial resistance and infection control · 2025Article
- Perils of the PICC: Peripherally Inserted Central Catheter-Associated Complications and Recommendations for Prevention in Clinical Practice-A Narrative Review.Healthcare (Basel, Switzerland) · 2025Review
- Case Report: Successful DSA-guided removal of a fractured PICC catheter from the pulmonary artery in a patient with lung cancer.Frontiers in oncology · 2025Article
- Effectiveness of Evidence-Based Continuous Quality Improvement in Reducing Peripherally Inserted Central Catheter Complications Among Premature Infants in China: A Four-Year Retrospective Study.Journal of multidisciplinary healthcare · 2025Article
- Antibiofilm and antithrombotic hydrogel coating based on superhydrophilic zwitterionic carboxymethyl chitosan for blood-contacting devices.Bioactive materials · 2024Article
- Supportive care needs of adults living with a peripherally inserted central catheter (PICC) at home: a qualitative content analysis.BMC nursing · 2024Article
- "AFGP" bundles for an extremely preterm infant who underwent difficult removal of a peripherally inserted central catheter: A case report.World journal of clinical cases · 2021Article
- Analysis of complications associated with peripherally inserted central venous catheters. Prospective observational study.Revista CuidarteArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPeripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems.
objectivesTo assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH
methodsThe University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN
resultsWe included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS'
conclusionsThere is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.