Evidence map›Paper›PMID 38938753›Full record

ArticleBioImpacts : BI2024

Micro-extraction, pre-concentration, and microfluidic-based separation of organophosphate insecticides followed by the miniaturized electrochemical detection system.

Abdollah Abdollahi Aghdam, Mohsen Chamanara, Reza Laripour, Mohsen Ebrahimi

Abstract read
In one paragraph

Article in BioImpacts : BI, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abdollah Abdollahi AghdamDepartment of Toxicology and Pharmacology, Faculty of Medicine, AJA University of ‎Medical Sciences, Tehran, Iran.
Mohsen ChamanaraDepartment of Toxicology and Pharmacology, Faculty of Medicine, AJA University of ‎Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-6201-2918
Reza LaripourDepartment of Social and Preventive Medicine, Faculty of Medicine, AJA University of ‎Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-2799-9876
Mohsen EbrahimiDepartment of Toxicology and Pharmacology, Faculty of Medicine, AJA University of ‎Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0001-6862-6972

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: A new analytical method based on the coupling of microextraction and microfluidics was developed and investigated for the pre-concentration, separation, and electrochemical detection of fenitrothion (FT) and parathion (PA) at the sub-ppm concentrations. Methods: In the first step, the microchip capillary electrophoresis technique was used to serve as a separation and detection system. Analytes were injected in the 40 mm long microchannel with 10 mm sidearms. Then, they were separated by applying a direct electrical field (+1800 V) between the buffer and detection reservoirs. 2-(n-morpholino)ethanesulfonic acid (MES) buffer (20 mM, pH 5) was used as a running buffer. The electrochemical detection was performed using three Pt microelectrodes with the width of working, counter, and reference electrodes (50, 250, and 250 µm, respectively) in the out-channel approach. Results: The system was devised to have the optimum detection potential equal to -1.2 V vs. pseudo-reference electrode. The dimensions of the SU-8 channel have 20 µm depth and 50 µm width. In the second step, an air-assisted liquid-liquid microextraction technique was used to extract and preconcentration of analytes from human blood plasma. Then, 1, 2 di-bromoethan was used as extractant solvent, the analytes were preconcentrated, and the sedimented solvent (50 µL) was evaporated in a 60 ˚C water bath followed by substitution of running buffer containing 10% ethanol. The optimal extraction cycles were found to be 8 with adding 1% NaCl to the aqueous phase. Analyzing time of the mentioned analytes was less than 100s, the precision range was 3.3 - 8.2 with a linear range of 0.8-100 ppm and 1.2-100 ppm for FT and PA, respectively. The extraction recoveries were about 91% and 87% for FT and PA, respectively. The detection limits for FT and PA were 240 and 360 ppb, respectively. Finally, the reliability of the method was investigated by GC-FID. Conclusion: The proposed method and device were validated and can be used as in situ and portable detection systems for detecting fenitrothion and parathion insecticides.

Indexed as

FenitrothionInsecticideMicroextractionMicrofluidicsOrganophosphateParathion

Identifiers

PMID38938753
PMCPMC11199932

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.