ArticleSensors (Basel, Switzerland)2024
Noninvasive Temperature Measurements in Tissue-Simulating Phantoms Using a Solid-State Near-Infrared Sensor.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The monitoring of body temperature is a recent addition to the plethora of parameters provided by wellness and fitness wearable devices. Current wearable temperature measurements are made at the skin surface, a measurement that is impacted by the ambient environment of the individual. The use of near-infrared spectroscopy provides the potential for a measurement below the epidermal layer of skin, thereby having the potential advantage of being more reflective of physiological conditions. The feasibility of noninvasive temperature measurements is demonstrated by using an in vitro model designed to mimic the near-infrared spectra of skin. A miniaturizable solid-state laser-diode-based near-infrared spectrometer was used to collect diffuse reflectance spectra for a set of seven tissue phantoms composed of different amounts of water, gelatin, and Intralipid. Temperatures were varied between 20-24 °C while collecting these spectra. Two types of partial least squares (PLS) calibration models were developed to evaluate the analytical utility of this approach. In both cases, the collected spectra were used without pre-processing and the number of latent variables was the only optimized parameter. The first approach involved splitting the whole dataset into separate calibration and prediction subsets for which a single optimized PLS model was developed. For this first case, the coefficient of determination (R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials