Evidence map›Paper›PMID 38931712›Full record

ArticleSensors (Basel, Switzerland)2024

Splitter-Based Sensors Realized via POFs Coupled by a Micro-Trench Filled with a Molecularly Imprinted Polymer.

Ines Tavoletta, Francesco Arcadio, Luca Pasquale Renzullo, Giuseppe Oliva, Domenico Del Prete, Debora Verolla, Chiara Marzano, Giancarla Alberti, Maria Pesavento, Luigi Zeni and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ines TavolettaDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
Francesco ArcadioDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.ORCID 0000-0001-7863-743X
Luca Pasquale RenzulloDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
Giuseppe OlivaDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
Domenico Del PreteDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
Debora VerollaDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
Chiara MarzanoDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.ORCID 0000-0003-1048-3790
Giancarla AlbertiDepartment of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.ORCID 0000-0003-4106-2219
Maria PesaventoDepartment of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy.
Luigi ZeniDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.ORCID 0000-0001-8356-7480
Nunzio CennamoDepartment of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.ORCID 0000-0001-7769-0984

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An optical-chemical sensor based on two modified plastic optical fibers (POFs) and a molecularly imprinted polymer (MIP) is realized and tested for the detection of 2-furaldehyde (2-FAL). The 2-FAL measurement is a scientific topic of great interest in different application fields, such as human health and life status monitoring in power transformers. The proposed sensor is realized by using two POFs as segmented waveguides (SW) coupled through a micro-trench milled between the fibers and then filled with a specific MIP for the 2-FAL detection. The experimental results show that the developed intensity-based sensor system is highly selective and sensitive to 2-FAL detection in aqueous solutions, with a limit of detection of about 0.04 mg L

Indexed as

2-furaldehyde (2-FAL)intensity-based sensorsmolecularly imprinted polymers (MIPs)optical–chemical sensorsplastic optical fibers (POFs)POF splitter

Identifiers

PMID38931712
PMCPMC11207874

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.