Evidence map›Paper›PMID 38931704›Full record

ArticleSensors (Basel, Switzerland)2024

Miniaturizable Chemiluminescence System for ATP Detection in Water.

Giuseppe E Capuano, Domenico Corso, Roberta Farina, Gianni Pezzotti Escobar, Giuseppe A Screpis, Maria Anna Coniglio, Sebania Libertino

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Giuseppe E CapuanoIstituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.ORCID 0000-0002-8430-8218
Domenico CorsoIstituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.
Roberta FarinaIstituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.ORCID 0000-0002-7884-8648
Gianni Pezzotti EscobarURT "LabSens of Beyond Nano" of the Department of Physical Sciences and Technologies of Matter, National Research Council (CNR-DSFTM-ME), Viale Ferdinando Stagno D'Alcontres 31, 98166 Messina, Italy.ORCID 0000-0002-1843-0880
Giuseppe A ScrepisDepartment of Medical, Surgical Sciences and Advanced Technologies, University of Catania, Via S. Sofia 78, 95123 Catania, Italy.
Maria Anna ConiglioIstituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.ORCID 0000-0002-6119-0309
Sebania LibertinoIstituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.ORCID 0000-0002-8844-8568

Funding

European Union (NextGeneration EU), MUR-PNRR ECS00000022European Union's Horizon 2020 Research and Innovation Program 101006941Italian University and Research Minister, PON ARS01_00333_TETI
6 · The paper itself

Abstract

We present the design, fabrication, and testing of a low-cost, miniaturized detection system that utilizes chemiluminescence to measure the presence of adenosine triphosphate (ATP), the energy unit in biological systems, in water samples. The ATP-luciferin chemiluminescent solution was faced to a silicon photomultiplier (SiPM) for highly sensitive real-time detection. This system can detect ATP concentrations as low as 0.2 nM, with a sensitivity of 79.5 A/M. Additionally, it offers rapid response times and can measure the characteristic time required for reactant diffusion and mixing within the reaction volume, determined to be 0.3 ± 0.1 s. This corresponds to a diffusion velocity of approximately 44 ± 14 mm

Indexed as

Adenosine TriphosphateLuminescent MeasurementsWaterBiosensing TechniquesLuminescenceAdenosine TriphosphateWaterATP bioluminescence detectionbacterial charge detectiondiffusion timeminiaturized sensing systemsilicon photomultiplier

Identifiers

PMID38931704
PMCPMC11207618

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.