ArticleSensors (Basel, Switzerland)2024
A Pressure and Proximity Sensor Based on Laser-Induced Graphene.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Neuromorphic Near-Sensor and In-Sensor Computing Enabled by Next-Generation Material-Based Sensors.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Smart wearable devices are extensively utilized across diverse domains due to their inherent advantages of flexibility, portability, and real-time monitoring. Among these, flexible sensors demonstrate exceptional pliability and malleability, making them a prominent focus in wearable electronics research. However, the implementation of flexible wearable sensors often entails intricate and time-consuming processes, leading to high costs, which hinder the advancement of the entire field. Here, we report a pressure and proximity sensor based on oxidized laser-induced graphene (oxidized LIG) as a dielectric layer sandwiched by patterned LIG electrodes, which is characterized by high speed and cost-effectiveness. It is found that in the low-frequency range of fewer than 0.1 kHz, the relative dielectric constant of the oxidized LIG layer reaches an order of magnitude of 104. The pressure mode of this bimodal capacitive sensor is capable of detecting pressures within the range of 1.34 Pa to 800 Pa, with a response time of several hundred milliseconds. The proximity mode involves the application of stimulation using an acrylic probe, which demonstrates a detection range from 0.05 mm to 37.8 mm. Additionally, it has a rapid response time of approximately 100 ms, ensuring consistent signal variations throughout both the approach and withdrawal phases. The sensor fabrication method proposed in this project effectively minimizes expenses and accelerates the preparation cycle through precise control of laser processing parameters to shape the electrode-dielectric layer-electrode within a single substrate material. Based on their exceptional combined performance, our pressure and proximity sensors exhibit significant potential in practical applications such as motion monitoring and distance detection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.