Evidence map›Paper›PMID 38931600›Full record

ArticleSensors (Basel, Switzerland)2024

Anatomical Registration of Implanted Sensors Improves Accuracy of Trunk Tilt Estimates with a Networked Neuroprosthesis.

Matthew W Morrison, Michael E Miller, Lisa M Lombardo, Ronald J Triolo, Musa L Audu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Matthew W MorrisonDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
Michael E MillerMotion Study Laboratory, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH 44106, USA.
Lisa M LombardoMotion Study Laboratory, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH 44106, USA.
Ronald J TrioloDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0003-0984-5803
Musa L AuduDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0001-5737-1708

Funding

U.S. Department of Defense W81XWH-22-1-0836
6 · The paper itself

Abstract

For individuals with spinal cord injuries (SCIs) above the midthoracic level, a common complication is the partial or complete loss of trunk stability in the seated position. Functional neuromuscular stimulation (FNS) can restore seated posture and other motor functions after paralysis by applying small electrical currents to the peripheral motor nerves. In particular, the Networked Neuroprosthesis (NNP) is a fully implanted, modular FNS system that is also capable of capturing information from embedded accelerometers for measuring trunk tilt for feedback control of stimulation. The NNP modules containing the accelerometers are located in the body based on surgical constraints. As such, their exact orientations are generally unknown and cannot be easily assessed. In this study, a method for estimating trunk tilt that employed the Gram-Schmidt method to reorient acceleration signals to the anatomical axes of the body was developed and deployed in individuals with SCI using the implanted NNP system. An anatomically realistic model of a human trunk and five accelerometer sensors was developed to verify the accuracy of the reorientation algorithm. Correlation coefficients and root mean square errors (RMSEs) were calculated to compare target trunk tilt estimates and tilt estimates derived from simulated accelerometer signals under a variety of conditions. Simulated trunk tilt estimates with correlation coefficients above 0.92 and RMSEs below 5° were achieved. The algorithm was then applied to accelerometer signals from implanted sensors installed in three NNP recipients. Error analysis was performed by comparing the correlation coefficients and RMSEs derived from trunk tilt estimates calculated from implanted sensor signals to those calculated via motion capture data, which served as the gold standard. NNP-derived trunk tilt estimates exhibited correlation coefficients between 0.80 and 0.95 and RMSEs below 13° for both pitch and roll in most cases. These findings suggest that the algorithm is effective at estimating trunk tilt with the implanted sensors of the NNP system, which implies that the method may be appropriate for extracting feedback signals for control systems for seated stability with NNP technology for individuals who have reduced control of their trunk due to paralysis.

Indexed as

AccelerometryAlgorithmsTorsoHumansNeural ProsthesesPostureSpinal Cord Injuriesmusculoskeletalnetworked neuroprosthesissensor reorientationspinal cord injurytrunk control

Identifiers

PMID38931600
PMCPMC11207283

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.