Evidence map›Paper›PMID 38931550›Full record

ArticleSensors (Basel, Switzerland)2024

A Guide to Measuring Heart and Respiratory Rates Based on Off-the-Shelf Photoplethysmographic Hardware and Open-Source Software.

Guylian Stevens, Luc Hantson, Michiel Larmuseau, Jan R Heerman, Vincent Siau, Pascal Verdonck

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guylian StevensDepartment of Electronics and Information Systems-IBiTech, Korneel Heymanslaan, Ghent University, 9000 Ghent, Belgium.ORCID 0000-0001-6689-2847
Luc HantsonH3CareSolutions, Henegouwestraat 41, 9000 Ghent, Belgium.
Michiel LarmuseauAZ Maria Middelares Hospital, Buitenring Sint-Denijs 30, 9000 Ghent, Belgium.
Jan R HeermanPartnership of Anesthesia of the AZ Maria Middelares Hospital, Buitenring Sint-Denijs 30, 9000 Ghent, Belgium.
Vincent SiauAlsico NV, Pont West, 9600 Ronse, Belgium.
Pascal VerdonckDepartment of Electronics and Information Systems-IBiTech, Korneel Heymanslaan, Ghent University, 9000 Ghent, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The remote monitoring of vital signs via wearable devices holds significant potential for alleviating the strain on hospital resources and elder-care facilities. Among the various techniques available, photoplethysmography stands out as particularly promising for assessing vital signs such as heart rate, respiratory rate, oxygen saturation, and blood pressure. Despite the efficacy of this method, many commercially available wearables, bearing Conformité Européenne marks and the approval of the Food and Drug Administration, are often integrated within proprietary, closed data ecosystems and are very expensive. In an effort to democratize access to affordable wearable devices, our research endeavored to develop an open-source photoplethysmographic sensor utilizing off-the-shelf hardware and open-source software components. The primary aim of this investigation was to ascertain whether the combination of off-the-shelf hardware components and open-source software yielded vital-sign measurements (specifically heart rate and respiratory rate) comparable to those obtained from more expensive, commercially endorsed medical devices. Conducted as a prospective, single-center study, the research involved the assessment of fifteen participants for three minutes in four distinct positions, supine, seated, standing, and walking in place. The sensor consisted of four PulseSensors measuring photoplethysmographic signals with green light in reflection mode. Subsequent signal processing utilized various open-source Python packages. The heart rate assessment involved the comparison of three distinct methodologies, while the respiratory rate analysis entailed the evaluation of fifteen different algorithmic combinations. For one-minute average heart rates' determination, the Neurokit process pipeline achieved the best results in a seated position with a Spearman's coefficient of 0.9 and a mean difference of 0.59 BPM. For the respiratory rate, the combined utilization of Neurokit and Charlton algorithms yielded the most favorable outcomes with a Spearman's coefficient of 0.82 and a mean difference of 1.90 BrPM. This research found that off-the-shelf components are able to produce comparable results for heart and respiratory rates to those of commercial and approved medical wearables.

Indexed as

Heart RatePhotoplethysmographyRespiratory RateSignal Processing, Computer-AssistedSoftwareWearable Electronic DevicesAdultAlgorithmsFemaleHumansMaleMonitoring, PhysiologicProspective Studiesconnected carephotoplethysmographytelemonitoringvital signs

Identifiers

PMID38931550
PMCPMC11207213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.