Evidence map›Paper›PMID 38931489›Full record

ArticleSensors (Basel, Switzerland)2024

Theoretical and Experimental Analysis of Single-Arm Bimodal Plasmo-Photonic Refractive Index Sensors.

Konstantinos Fotiadis, Evangelia Chatzianagnostou, Dimosthenis Spasopoulos, Stelios Simos, Dimitris V Bellas, Omkar Bhalerao, Stephan Suckow, Max C Lemme, Elefterios Lidorikis, Nikos Pleros

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Theoretical Analysis of Efficient Thermo-Optic Switching on SiNanomaterials (Basel, Switzerland) · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Konstantinos FotiadisDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Evangelia ChatzianagnostouDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Dimosthenis SpasopoulosDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Stelios SimosDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.ORCID 0000-0002-0776-3532
Dimitris V BellasDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
Omkar BhaleraoAMO GmbH, Advanced Microelectronic Center Aachen, 52074 Aachen, Germany.ORCID 0000-0001-9738-3121
Stephan SuckowAMO GmbH, Advanced Microelectronic Center Aachen, 52074 Aachen, Germany.ORCID 0000-0002-1116-169X
Max C LemmeAMO GmbH, Advanced Microelectronic Center Aachen, 52074 Aachen, Germany.ORCID 0000-0003-4552-2411
Elefterios LidorikisDepartment of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece.ORCID 0000-0002-9552-9366
Nikos PlerosDepartment of Informatics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.

Funding

AMBROSIA 101093166ICT-GRACED 101007448
6 · The paper itself

Abstract

In this paper, we study both theoretically and experimentally the sensitivity of bimodal interferometric sensors where interference occurs between two plasmonic modes with different properties propagating in the same physical waveguide. In contrast to the well-known Mach-Zehnder interferometric (MZI) sensor, we show for the first time that the sensitivity of the bimodal sensor is independent of the sensing area length. This is validated by applying the theory to an integrated plasmo-photonic bimodal sensor that comprises an aluminum (Al) plasmonic stripe waveguide co-integrated between two accessible SU-8 photonic waveguides. A series of such bimodal sensors utilizing plasmonic stripes of different lengths were numerically simulated, demonstrating bulk refractive index (RI) sensitivities around 5700 nm/RIU for all sensor variants, confirming the theoretical results. The theoretical and numerical results were also validated experimentally through chip-level RI sensing experiments on three fabricated SU-8/Al bimodal sensors with plasmonic sensing lengths of 50, 75, and 100 μm. The obtained experimental RI sensitivities were found to be very close and equal to 4464, 4386, and 4362 nm/RIU, respectively, confirming that the sensing length has no effect on the bimodal sensor sensitivity. The above outcome alleviates the design and optical loss constraints, paving the way for more compact and powerful sensors that can achieve high sensitivity values at ultra-short sensing lengths.

Indexed as

bimodalco-integrationplasmonicrefractive index sensorsensing area lengthsensitivitySU-8 photonic waveguide

Identifiers

PMID38931489
PMCPMC11207750

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.