Evidence map›Paper›PMID 38930772›Full record

ArticleMicromachines2024

A High-Aspect-Ratio Deterministic Lateral Displacement Array for High-Throughput Fractionation.

Jonathan Kottmeier, Maike S Wullenweber, Ingo Kampen, Arno Kwade, Andreas Dietzel

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jonathan KottmeierInstitute of Microtechnology, TU Braunschweig, 38124 Braunschweig, Germany.ORCID 0000-0001-7304-8935
Maike S WullenweberCenter of Pharmaceutical Engineering (PVZ), TU Braunschweig, 38106 Braunschweig, Germany.ORCID 0000-0002-6187-1761
Ingo KampenCenter of Pharmaceutical Engineering (PVZ), TU Braunschweig, 38106 Braunschweig, Germany.
Arno KwadeCenter of Pharmaceutical Engineering (PVZ), TU Braunschweig, 38106 Braunschweig, Germany.ORCID 0000-0002-6348-7309
Andreas DietzelInstitute of Microtechnology, TU Braunschweig, 38124 Braunschweig, Germany.ORCID 0000-0003-2090-6259

Funding

Deutsche Forschungsgemeinschaft SPP 2045
6 · The paper itself

Abstract

Future industrial applications of microparticle fractionation with deterministic lateral displacement (DLD) devices are hindered by exceedingly low throughput rates. To enable the necessary high-volume flows, high flow velocities as well as high aspect ratios in DLD devices have to be investigated. However, no experimental studies have yet been conducted on the fractionation of bi-disperse suspensions containing particles below 10 µm with DLD at a Reynolds number (Re) above 60. Furthermore, devices with an aspect ratio of more than 4:1, which require advanced microfabrication, are not known in the DLD literature. Therefore, we developed a suitable process with deep reactive ion etching of silicon and anodic bonding of a glass lid to create pressure-resistant arrays. With a depth of 120 µm and a gap of 23 µm between posts, a high aspect ratio of 6:1 was realized, and devices were investigated using simulations and fractionation experiments. With the two-segmented array of 3° and 7° row shifts, critical diameters of 8 µm and 12 µm were calculated for low Re conditions, but it was already known that vortices behind the posts can shift these values to lower critical diameters. Suspensions with polystyrene particles in different combinations were injected with an overall flow rate of up to 15 mL/min, corresponding to Re values of up to 90. Suspensions containing particle combinations of 2 µm with 10 µm as well as 5 µm with 10 µm were successfully fractionated, even at the highest flow rate. Under these conditions, a slight widening of the displacement position was observed, but there was no further reduction in the critical size as it was for Re = 60. With an unprecedented fractionation throughput of nearly 1 L per hour, entirely new applications are being developed for chemical, pharmaceutical, and recycling technologies.

Indexed as

deterministic lateral displacement (DLD)high aspect ratiohigh throughputmicrofluidicssize-dependent fractionation

Identifiers

PMID38930772
PMCPMC11205752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.