Evidence map›Paper›PMID 38930697›Full record

ArticleMicromachines2024

Responsiveness and Precision of Digital IMUs under Linear and Curvilinear Motion Conditions for Local Navigation and Positioning in Advanced Smart Mobility.

Luciano Chiominto, Emanuela Natale, Giulio D'Emilia, Sante Alessandro Grieco, Andrea Prato, Alessio Facello, Alessandro Schiavi

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Luciano ChiomintoDepartment of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy.ORCID 0000-0001-6380-7029
Emanuela NataleDepartment of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy.ORCID 0000-0002-4547-0538
Giulio D'EmiliaDepartment of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy.ORCID 0000-0002-9285-3355
Sante Alessandro GriecoDepartment of Engineering "Enzo Ferrari", University of Modena and Reggio Emilia, 41125 Modena, Italy.
Andrea PratoDivision of Applied Metrology and Engineering INRiM-National Institute of Metrological Research, 10135 Turin, Italy.ORCID 0000-0003-3733-4189
Alessio FacelloDivision of Applied Metrology and Engineering INRiM-National Institute of Metrological Research, 10135 Turin, Italy.ORCID 0000-0001-5840-9296
Alessandro SchiaviDivision of Applied Metrology and Engineering INRiM-National Institute of Metrological Research, 10135 Turin, Italy.ORCID 0000-0003-4168-3605

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Sensors based on MEMS technology, in particular Inertial Measurement Units (IMUs), when installed on vehicles, provide a real-time full estimation of vehicles' state vector (e.g., position, velocity, yaw angle, angular rate, acceleration), which is required for the planning and control of cars' trajectories, as well as managing the in-car local navigation and positioning tasks. Moreover, data provided by the IMUs, integrated with the data of multiple inputs from other sensing systems (such as Lidar, cameras, and GPS) within the vehicle, and with the surrounding information exchanged in real time (vehicle to vehicle, vehicle to infrastructure, or vehicle to other entities), can be exploited to actualize the full implementation of "smart mobility" on a large scale. On the other hand, "smart mobility" (which is expected to improve road safety, reduce traffic congestion and environmental burden, and enhance the sustainability of mobility as a whole), to be safe and functional on a large scale, should be supported by highly accurate and trustworthy technologies based on precise and reliable sensors and systems. It is known that the accuracy and precision of data supplied by appropriately in-lab-calibrated IMUs (with respect to the primary or secondary standard in order to provide traceability to the International System of Units) allow guaranteeing high quality, reliable information managed by processing systems, since they are reproducible, repeatable, and traceable. In this work, the effective responsiveness and the related precision of digital IMUs, under sinusoidal linear and curvilinear motion conditions at 5 Hz, 10 Hz, and 20 Hz, are investigated on the basis of metrological approaches in laboratory standard conditions only. As a first step, in-lab calibrations allow one to reduce the variables of uncontrolled boundary conditions (e.g., occurring in vehicles in on-site tests) in order to identify the IMUs' sensitivity in a stable and reproducible environment. For this purpose, a new calibration system, based on an oscillating rotating table was developed to reproduce the dynamic conditions of use in the field, and the results are compared with calibration data obtained on linear calibration benches.

Indexed as

curvilinear motiondigital IMUin-lab calibrationprecision

Identifiers

PMID38930697
PMCPMC11205907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.