Evidence map›Paper›PMID 38930669›Full record

ArticleMicromachines2024

Micro- and Nanofluidic pH Sensors Based on Electrodiffusioosmosis.

Tadashi Takagi, Tatsunori Kishimoto, Kentaro Doi

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tadashi TakagiDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Aichi, Japan.
Tatsunori KishimotoDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Aichi, Japan.
Kentaro DoiDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8580, Aichi, Japan.ORCID 0000-0002-2663-9369

Funding

JSPS KAKENHI JP21H01246 and JP22H05140JST FOREST Program JPMFJR203L
6 · The paper itself

Abstract

Recently, various kinds of micro- and nanofluidic functional devices have been proposed, where a large surface-to-volume ratio often plays an important role in nanoscale ion transport phenomena. Ionic current analysis methods for ions, molecules, nanoparticles, and biological cells have attracted significant attention. In this study, focusing on ionic current rectification (ICR) caused by the separation of cation and anion transport in nanochannels, we successfully induce electrodiffusioosmosis with concentration differences between protons separated by nanochannels. The proton concentration in sample solutions is quantitatively evaluated in the range from pH 1.68 to 10.01 with a slope of 243 mV/pH at a galvanostatic current of 3 nA. Herein, three types of micro- and nanochannels are proposed to improve the stability and measurement accuracy of the current-voltage characteristics, and the ICR effects on pH analysis are evaluated. It is found that a nanochannel filled with polyethylene glycol exhibits increased impedance and an improved ICR ratio. The present principle is expected to be applicable to various types of ions.

Indexed as

electrodiffusioosmosisionic current rectificationion selectivitynanochannelpH sensor

Identifiers

PMID38930669
PMCPMC11205811

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.