The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants.

Darcio Fonseca, Beatriz de Tapia, Ramon Pons, Conrado Aparicio, Fernando Guerra, Ana Messias, Javier Gil

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Darcio FonsecaBioengineering Institute of Technology, Medicine and Health Sciences Faculty, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain.
Beatriz de TapiaDepartment of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain.ORCID 0000-0001-5542-7659
Ramon PonsDepartment of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain.
Conrado AparicioDepartment of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain.ORCID 0000-0003-2969-6067
Fernando GuerraDepartment Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal.ORCID 0000-0001-8780-9379
Ana MessiasDepartment Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal.
Javier GilDepartment Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal.ORCID 0000-0002-6824-1412

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium surface makes it possible to eliminate bacterial colonies, but it can generate variations in the properties of the implant. These variations, especially those in fatigue resistance and electrochemical corrosion behavior, have not been studied much. In this work, fatigue tests were performed on 60 dental implants without implantoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, and 60 with implatoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, using triaxial tension-compression and torsion stresses simulating human chewing. Mechanical tests were performed with a Bionix servo-hydraulic testing machine and fracture surfaces were studied by scanning electron microcopyElectrochemical corrosion tests were performed on 20 dental implants to determine the corrosion potentials and corrosion intensity for control implants and implantoplasty implants. Studies of titanium ion release to the physiological medium were carried out for each type of dental implants by Inductively Coupled-Plasma Mass Spectrometry at different immersion times at 37 °C. The results show a loss of fatigue caused by the implantoplasty of 30%, observing that the nucleation points of the cracks are in the areas of high deformation in the areas of the implant neck where the mechanization produced in the treatment of the implantoplasty causes an exaltation of fatigue cracks. It has been observed that tests performed in Hank's solution reduce the fatigue life due to the incorporation of hydrogen in the titanium causing the formation of hydrides that embrittle the dental implant. Likewise, the implantoplasty causes a reduction of the corrosion resistance with some pitting on the machined surface. Ion release analyses are slightly higher in the implantoplasted samples but do not show statistically significant differences. It has been observed that the physiological environment reduces the fatigue life of the implants due to the penetration of hydrogen into the titanium forming titanium hydrides which embrittle the implant. These results should be taken into account by clinicians to determine the convenience of performing a treatment such as implantoplasty that reduces the mechanical behavior and increases the chemical degradation of the titanium dental implant.

Indexed as

corrosion resistancefatigueimplantopalstyion releasemechanical propertiestitanium

Identifiers

PMID38930312
PMCPMC11206074

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.