ArticleDiagnostics (Basel, Switzerland)2024
Classical Orbital Floor Post-Traumatic Reconstruction vs. Customized Reconstruction with the Support of "In-House" 3D-Printed Models: A Retrospective Study with an Analysis of Volumetric Measurement.
Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Impact of In-House 3D-Printed Models on Re-Operation Rates and Volumetric Precision in Orbital Floor Reconstruction: A Comparative Study.Journal of clinical medicine · 2026Article
- Bioprinting for craniofacial reconstruction: A review of advancements, clinical use, and challenges.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOrbital floor fractures (OFFs) represent an interesting chapter in maxillofacial surgery, and one of the main challenges in orbit reconstruction is shaping and cutting the precise contour of the implants due to its complex anatomy.
objectiveThe aim of the retrospective study was to demonstrate, through pre- and postoperative volumetric measurements of the orbit, how the use of a preformed titanium mesh based on the stereolithographic model produced with 3D printers ("In-House" reconstruction) provides a better reconstruction volumetric compared to the intraoperatively shaped titanium mesh. MATERIALS AND
methodsThe patients with OFF enrolled in this study were divided into two groups according to the inclusion criteria. In Group 1 (G1), patients surgically treated for OFF were divided into two subgroups: G1a, patients undergoing orbital floor reconstruction with an intraoperatively shaped mesh, and G1b, patients undergoing orbital floor reconstruction with a preoperative mesh shaped on a 3D-printed stereolithographic model. Group 2 (G2) consisted of patients treated for other traumatic pathologies (mandible fractures and middle face fractures not involving orbit). Pre- and postoperative orbital volumetric measurements were performed on both G1 and G2. The patients of both groups were subjected to the measurement of orbital volume using Osirix software (Pixmeo SARL, CH-1233 Bernex, Switzerland) on the new CT examination. Both descriptive (using central tendency indices such as mean and range) and regressive (using the Bravais-Pearson index, calculated using the GraphPad program) statistical analyses were performed on the recorded data.
resultsFrom 1 January 2017 to 31 December 2021, of the 176 patients treated for OFF at the "Magna Graecia" University Hospital of Catanzaro 10 fulfilled the study's inclusion criteria: 5 were assigned to G1a and 5 to G1b, with a total of 30 volumetric measurements. In G2, we included 10 patients, with a total of 20 volumetric measurements. From the volumetric measurements and statistical analysis carried out, it emerged that the average of the volumetric differences of the healthy orbits was ±0.6351 cm
conclusionThis study demonstrates that if the volume is restored within the range of the standardized mean, the diplopia is completely recovered already after surgery or after one month. For orbital volumes that do not fall within this range, functional recovery could occur within 6 months or be lacking. The restoration of the orbital volume using pre-modeled networks on the patient's anatomical model, printed internally in 3D, allows for more accurate reconstructions of the orbital floor in less time, with clinical advantages also in terms of surgical timing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials