Evidence map›Paper›PMID 38927852›Full record

ArticleBioengineering (Basel, Switzerland)2024

Investigating the Feasibility and Performance of Hybrid Overmolded UHMWPE 3D-Printed PEEK Structural Composites for Orthopedic Implant Applications: A Pilot Study.

James A Smith, Cemile Basgul, Bita Soltan Mohammadlou, Mark Allen, Steven M Kurtz

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. A novel UHMWPE anchor for improving the pullout resistance of pedicle screws.Frontiers in bioengineering and biotechnology · 2026
    Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

James A SmithImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Cemile BasgulImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Bita Soltan MohammadlouDepartment of Mechanical Engineering, Drexel University, Philadelphia, PA 19104, USA.
Mark AllenOrthoplastics, Bacup OL13 9EF, UK.
Steven M KurtzImplant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA 19104, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultra-high-molecular-weight polyethylene (UHMWPE) components for orthopedic implants have historically been integrated into metal backings by direct-compression molding (DCM). However, metal backings are costly, stiffer than cortical bone, and may be associated with medical imaging distortion and metal release. Hybrid-manufactured DCM UHMWPE overmolded additively manufactured polyetheretherketone (PEEK) structural components could offer an alternative solution, but are yet to be explored. In this study, five different porous topologies (grid, triangular, honeycomb, octahedral, and gyroid) and three surface feature sizes (low, medium, and high) were implemented into the top surface of digital cylindrical specimens prior to being 3D printed in PEEK and then overmolded with UHMWPE. Separation forces were recorded as 1.97-3.86 kN, therefore matching and bettering the historical industry values (2-3 kN) recorded for DCM UHMWPE metal components. Infill topology affected failure mechanism (Type 1 or 2) and obtained separation forces, with shapes having greater sidewall numbers (honeycomb-60%) and interconnectivity (gyroid-30%) through their builds, tolerating higher transmitted forces. Surface feature size also had an impact on applied load, whereby those with low infill-%s generally recorded lower levels of performance vs. medium and high infill strategies. These preliminary findings suggest that hybrid-manufactured structural composites could replace metal backings and produce orthopedic implants with high-performing polymer-polymer interfaces.

Indexed as

3D printingadditive manufacturinghybrid manufacturingmaterial extrusionpolyetheretherketoneporosityultra-high molecular weight polyethylene