Evidence map›Paper›PMID 38927813›Full record

ArticleBioengineering (Basel, Switzerland)2024

Integrating Deep Learning with Electronic Health Records for Early Glaucoma Detection: A Multi-Dimensional Machine Learning Approach.

Alireza Karimi, Ansel Stanik, Cooper Kozitza, Aiyin Chen

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alireza KarimiDepartment of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, Portland, OR 97239, USA.
Ansel StanikDepartment of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, Portland, OR 97239, USA.ORCID 0009-0009-7607-5723
Cooper KozitzaDepartment of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, Portland, OR 97239, USA.ORCID 0009-0002-7781-0848
Aiyin ChenDepartment of Ophthalmology, Casey Eye Institute, Oregon Health and Science University, Portland, OR 97239, USA.ORCID 0000-0002-2125-948X

Funding

Modulation of Outflow Facility and BiomechanicsR01EY036011 · NEI · OREGON HEALTH & SCIENCE UNIVERSITY · PI Alireza Karimi · 2024 to 2026
$1.2M
NEI NIH HHS EY036011NEI NIH HHS GCAEI0492ENEI NIH HHS R01 EY036011Research to Prevent Blindness NA
6 · The paper itself

Abstract

backgroundRecent advancements in deep learning have significantly impacted ophthalmology, especially in glaucoma, a leading cause of irreversible blindness worldwide. In this study, we developed a reliable predictive model for glaucoma detection using deep learning models based on clinical data, social and behavior risk factor, and demographic data from 1652 participants, split evenly between 826 control subjects and 826 glaucoma patients.

methodsWe extracted structural data from control and glaucoma patients' electronic health records (EHR). Three distinct machine learning classifiers, the Random Forest and Gradient Boosting algorithms, as well as the Sequential model from the Keras library of TensorFlow, were employed to conduct predictive analyses across our dataset. Key performance metrics such as accuracy, F1 score, precision, recall, and the area under the receiver operating characteristics curve (AUC) were computed to both train and optimize these models.

resultsThe Random Forest model achieved an accuracy of 67.5%, with a ROC AUC of 0.67, outperforming the Gradient Boosting and Sequential models, which registered accuracies of 66.3% and 64.5%, respectively. Our results highlighted key predictive factors such as intraocular pressure, family history, and body mass index, substantiating their roles in glaucoma risk assessment.

conclusionsThis study demonstrates the potential of utilizing readily available clinical, lifestyle, and demographic data from EHRs for glaucoma detection through deep learning models. While our model, using EHR data alone, has a lower accuracy compared to those incorporating imaging data, it still offers a promising avenue for early glaucoma risk assessment in primary care settings. The observed disparities in model performance and feature significance show the importance of tailoring detection strategies to individual patient characteristics, potentially leading to more effective and personalized glaucoma screening and intervention.

Indexed as

clinical dataearly detectionglaucomamachine learning algorithms

Identifiers

PMID38927813
PMCPMC11200568

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.