Evidence map›Paper›PMID 38926876›Full record

ArticleJournal of neuroengineering and rehabilitation2024

Wearable biofeedback device to assess gait features and improve gait pattern in people with parkinson's disease: a case series.

Thomas Bowman, Andrea Pergolini, Maria Chiara Carrozza, Tiziana Lencioni, Alberto Marzegan, Mario Meloni, Nicola Vitiello, Simona Crea, Davide Cattaneo

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Review
  7. Wearable Online Freezing of Gait Detection and Cueing System.Bioengineering (Basel, Switzerland) · 2024
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Thomas Bowman *IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy. tbowman@dongnocchi.it.
Andrea Pergolini *The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, 56127, Italy.
Maria Chiara CarrozzaThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, 56127, Italy.
Tiziana LencioniIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Alberto MarzeganIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Mario MeloniIRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.
Nicola VitielloThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, 56127, Italy.
Simona Crea *The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, 56127, Italy.
Davide Cattaneo *IRCCS Fondazione Don Carlo Gnocchi, Milan, Italy.

Funding

CYBERLEGs Plus Plus project within the H2020 framework 731931Ministero della Salute Ricerca corrente 2021
6 · The paper itself

Abstract

introductionPeople with Parkinson's Disease (PD) show abnormal gait patterns compromising their independence and quality of life. Among all gait alterations due to PD, reduced step length, increased cadence, and decreased ground-reaction force during the loading response and push-off phases are the most common. Wearable biofeedback technologies offer the possibility to provide correlated single or multi-modal stimuli associated with specific gait events or gait performance, hence promoting subjects' awareness of their gait disturbances. Moreover, the portability and applicability in clinical and home settings for gait rehabilitation increase the efficiency in the management of PD. The Wearable Vibrotactile Bidirectional Interface (BI) is a biofeedback device designed to extract gait features in real-time and deliver a customized vibrotactile stimulus at the waist of PD subjects synchronously with specific gait phases. The aims of this study were to measure the effect of the BI on gait parameters usually compromised by the typical bradykinetic gait and to assess its usability and safety in clinical practice.

methodsIn this case series, seven subjects (age: 70.4 ± 8.1 years; H&Y: 2.7 ± 0.3) used the BI and performed a test on a 10-meter walkway (10mWT) and a two-minute walk test (2MWT) as pre-training (Pre-trn) and post-training (Post-trn) assessments. Gait tests were executed in random order with (Bf) and without (No-Bf) the activation of the biofeedback stimulus. All subjects performed three training sessions of 40 min to familiarize themselves with the BI during walking activities. A descriptive analysis of gait parameters (i.e., gait speed, step length, cadence, walking distance, double-support phase) was carried out. The 2-sided Wilcoxon sign-test was used to assess differences between Bf and No-Bf assessments (p < 0.05).

resultsAfter training subjects improved gait speed (Pre-trn_No-Bf: 0.72(0.59,0.72) m/sec; Post-trn_Bf: 0.95(0.69,0.98) m/sec; p = 0.043) and step length (Pre-trn_No-Bf: 0.87(0.81,0.96) meters; Post-trn_Bf: 1.05(0.96,1.14) meters; p = 0.023) using the biofeedback during the 10mWT. Similarly, subjects' walking distance improved (Pre-trn_No-Bf: 97.5 (80.3,110.8) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.028) and the duration of the double-support phase decreased (Pre-trn_No-Bf: 29.7(26.8,31.7) %; Post-trn_Bf: 27.2(24.6,28.7) %; p = 0.018) during the 2MWT. An immediate effect of the BI was detected in cadence (Pre-trn_No-Bf: 108(103.8,116.7) step/min; Pre-trn_Bf: 101.4(96.3,111.4) step/min; p = 0.028) at Pre-trn, and in walking distance at Post-trn (Post-trn_No-Bf: 112.5(97.5,124.5) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.043). SUS scores were 77.5 in five subjects and 80.3 in two subjects. In terms of safety, all subjects completed the protocol without any adverse events.

conclusionThe BI seems to be usable and safe for PD users. Temporal gait parameters have been measured during clinical walking tests providing detailed outcomes. A short period of training with the BI suggests improvements in the gait patterns of people with PD. This research serves as preliminary support for future integration of the BI as an instrument for clinical assessment and rehabilitation in people with PD, both in hospital and remote environments.

trial registrationThe study protocol was registered (DGDMF.VI/P/I.5.i.m.2/2019/1297) and approved by the General Directorate of Medical Devices and Pharmaceutical Service of the Italian Ministry of Health and by the ethics committee of the Lombardy region (Milan, Italy).

Indexed as

Biofeedback, PsychologyGait Disorders, NeurologicParkinson DiseaseWearable Electronic DevicesAgedFemaleGaitHumansMaleMiddle AgedAssessmentBiofeedbackGait parametersParkinson’s diseaseRehabilitationWearable device

Identifiers

PMID38926876
PMCPMC11202340

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked