Evidence map›Paper›PMID 38926711›Full record

ArticleBMC medical imaging2024

Deep learning image reconstruction generates thinner slice iodine maps with improved image quality to increase diagnostic acceptance and lesion conspicuity: a prospective study on abdominal dual-energy CT.

Jingyu Zhong, Lingyun Wang, Chao Yan, Yue Xing, Yangfan Hu, Defang Ding, Xiang Ge, Jianying Li, Wei Lu, Xiaomeng Shi and 3 more

Abstract read
In one paragraph

Article in BMC medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Jingyu Zhong *Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.ORCID http://orcid.org/0000-0002-9817-2294
Lingyun Wang *Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
Chao Yan *Department of Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
Yue XingDepartment of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
Yangfan HuDepartment of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
Defang DingDepartment of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
Xiang GeDepartment of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
Jianying LiComputed Tomography Research Center, GE Healthcare, Beijing, 100176, China.
Wei LuComputed Tomography Research Center, GE Healthcare, Shanghai, 201203, China.
Xiaomeng ShiDepartment of Materials, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
Fei YuanDepartment of Pathology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. daphny2014@163.com.
Weiwu YaoDepartment of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China. YWW4142@shtrhospital.com.
Huan ZhangDepartment of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. Zh10765@rjh.com.cn.

Funding

Guangci Innovative Technology Launch Plan of Ruijin Hospital, Shanghai Jiao Tong University School of Medicine YW20220014Laboratory Open Fund of Key Technology and Materials in Minimally Invasive Spine Surgery 2024JZWC-YBA07Laboratory Open Fund of Key Technology and Materials in Minimally Invasive Spine Surgery 2024JZWC-ZDA03National Natural Science Foundation of China 82271934National Natural Science Foundation of China 82302183Research Found of Health Commission of Changing District, Shanghai Municipality 2023QN01Research Fund of Tongren Hospital, Shanghai Jiao Tong University School of Medicine TRGG202101Research Fund of Tongren Hospital, Shanghai Jiao Tong University School of Medicine TRKYRC-XX20220Research Fund of Tongren Hospital, Shanghai Jiao Tong University School of Medicine TRYXJH18Research Fund of Tongren Hospital, Shanghai Jiao Tong University School of Medicine TRYXJH28Yangfan Project of Science and Technology Commission of Shanghai Municipality 22YF1442400
6 · The paper itself

Abstract

backgroundTo assess the improvement of image quality and diagnostic acceptance of thinner slice iodine maps enabled by deep learning image reconstruction (DLIR) in abdominal dual-energy CT (DECT).

methodsThis study prospectively included 104 participants with 136 lesions. Four series of iodine maps were generated based on portal-venous scans of contrast-enhanced abdominal DECT: 5-mm and 1.25-mm using adaptive statistical iterative reconstruction-V (Asir-V) with 50% blending (AV-50), and 1.25-mm using DLIR with medium (DLIR-M), and high strength (DLIR-H). The iodine concentrations (IC) and their standard deviations of nine anatomical sites were measured, and the corresponding coefficient of variations (CV) were calculated. Noise-power-spectrum (NPS) and edge-rise-slope (ERS) were measured. Five radiologists rated image quality in terms of image noise, contrast, sharpness, texture, and small structure visibility, and evaluated overall diagnostic acceptability of images and lesion conspicuity.

resultsThe four reconstructions maintained the IC values unchanged in nine anatomical sites (all p > 0.999). Compared to 1.25-mm AV-50, 1.25-mm DLIR-M and DLIR-H significantly reduced CV values (all p < 0.001) and presented lower noise and noise peak (both p < 0.001). Compared to 5-mm AV-50, 1.25-mm images had higher ERS (all p < 0.001). The difference of the peak and average spatial frequency among the four reconstructions was relatively small but statistically significant (both p < 0.001). The 1.25-mm DLIR-M images were rated higher than the 5-mm and 1.25-mm AV-50 images for diagnostic acceptability and lesion conspicuity (all P < 0.001).

conclusionsDLIR may facilitate the thinner slice thickness iodine maps in abdominal DECT for improvement of image quality, diagnostic acceptability, and lesion conspicuity.

Indexed as

Contrast MediaDeep LearningRadiographic Image Interpretation, Computer-AssistedRadiography, AbdominalRadiography, Dual-Energy Scanned ProjectionTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansIodineMaleMiddle AgedProspective StudiesContrast MediaIodineAbdomenDeep learningImage enhancementImage reconstructionMultidetector computed tomography

Identifiers

PMID38926711
PMCPMC11201298

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.