Evidence map›Paper›PMID 38926014›Full record

ArticleDental materials : official publication of the Academy of Dental Materials2024

An in vitro evaluation of the fatigue behavior of resin composite materials as part of a translational research cycle.

L A M J Crins, N J M Opdam, M C D N J M Huysmans, Y Zhang, B A C Loomans

Abstract read
In one paragraph

Article in Dental materials : official publication of the Academy of Dental Materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

L A M J CrinsRadboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands. Electronic address: Luuk.Crins@radboudumc.nl.
N J M OpdamRadboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands.
M C D N J M HuysmansRadboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands.
Y ZhangDepartment of Preventive & Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 109 Levy Buidling, Philadelphia, USA.
B A C LoomansRadboud University Medical Center, Department of Dentistry, P.O. Box 9101, Nijmegen 6525 EX, the Netherlands.

Funding

Viscoelastic Modeling Aided Experimental Optimization toward Fracture-Resistant Porcelain-Veneered Zirconia and Lithium Disilicate RestorationsR01DE026279 · NIDCR · UNIVERSITY OF PENNSYLVANIA · PI KIM, JEONGHO, ZHANG, YU · 2017 to 2021
$2.0M
Ultrafast sintering of dental zirconia: composition-processing-property relationships with high-throughput fail-fast screeningR01DE033545 · NIDCR · UNIVERSITY OF PENNSYLVANIA · PI Liangbing Hu, Yu Zhang · 2023 to 2026
$1.8M
NIDCR NIH HHS R01 DE026279NIDCR NIH HHS R01 DE033545
6 · The paper itself

Abstract

purposeThis study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP). MATERIALS AND

methodsFour dental resin composites were selected. 30 discs (Ø12.0 mm, 1.2 mm thick) were fabricated for each of Clearfil TM AP-X (AP), Filtek TM Supreme XTE (FS), Estenia TM C&B (ES), and Lava Ultimate (LU). Cyclic loading (200 N, 2 Hz frequency) was applied concentrically to 15 specimens per group with a spherical steatite indenter (r = 3.18 mm) in water in a contact-load-slide-liftoff motion (105 cycles). The wear scar was analysed using profilometry and the volume loss was digitally computed. Finally, all specimens were loaded (fatigued specimens with their worn surface loaded in tension) until fracture in a biaxial flexure apparatus. The differences in volume loss and flexural strength were determined using regression analysis.

resultsCompared to AP and FS, ES and LU showed a significantly lower volume loss (p < 0.05). Non-fatigued ES specimens had a similar flexural strength compared to nonfatigued AP, while non-fatigued FS and LU specimens had a lower flexural strength (p < 0.001; 95 %CI: -80.0 - 51.8). The fatigue test resulted in a significant decrease of the flexural strength of ES specimens, only (p < 0.001; 95 %CI: -96.1 - -54.6). CLINICAL RELEVANCE: These outcomes concur with the outcomes of clinical studies on the longevity of these composites in patients with tooth wear. Therefore, the employed laboratory test seems to have the potential to test materials in a clinically relevant way.

Indexed as

Composite ResinsFlexural StrengthMaterials TestingDental Restoration WearDental Stress AnalysisHumansIn Vitro TechniquesSurface PropertiesTooth WearTranslational Research, BiomedicalComposite ResinsCAD/CAMComposite resinsFatigue resistanceFracture resistanceSliding contactWear rate

Identifiers

PMID38926014
PMCPMC11330355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.