ArticleJournal of applied clinical medical physics2024
A robust index for metal artifact quantification in computed tomography.
Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Optimizing virtual monoenergetic imaging for dual‑energy CT venography assessment of intracranial venous sinus stents.Neuroradiology · 2026Article
- Dual-Filament 3D Printing of Patient-Specific CT Phantoms with Embedded Implants and Tunable Metal-Artifact Intensity.medRxiv : the preprint server for health sciences · 2026Article
- Quantitative phantom-based comparison of commercial CT metal artifact reduction algorithms.Journal of applied clinical medical physics · 2026Article
- The potential of high-Z contrast media for vessel visualization near metal implants: a photon-counting detector CT phantom study with virtual monoenergetic images and iterative metal artifact reduction.Quantitative imaging in medicine and surgery · 2026Article
- A Hybrid Approach Combining Dual-Energy and Inpainting Methods for Metal Artifact Reduction in Dentomaxillofacial CBCT: A Proof-of-Concept Phantom Study.Annals of biomedical engineering · 2025Article
- Effectiveness of single-energy metal artifact reduction algorithm in CT: application to contrast-enhanced CT with EVAR and coil embolization.The international journal of cardiovascular imaging · 2025Article
- A robust index for metal artifact quantification in computed tomography.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundObjective assessment of metal artifact strength and the effectiveness of metal artifact reduction algorithms in computed tomography requires a quantitative metric. Metrics described in the literature are typically employed to compare the artifact strength in images reconstructed from the same raw data, but their robustness against varying scan conditions and repeated scans over time as it occurs in periodic quality assurance has not been investigated. PURPOSE: A new robust metric for quantifying metal artifacts in computed-tomography images is proposed and compared to other commonly used metrics.
methodsThe proposed artifact metric is based on the location parameter of the Gumbel distribution, described previously in the literature, but normalized to the location parameter in a background region-of-interest to obtain a noise-independent artifact metric. The metric was compared to three other quantitative metal artifact metrics (artifact-index, contrast-to-noise ratio, Gumbel-evaluation method) by evaluating metals artifacts in phantom scans and in clinical images. Robustness of the artifact metrics was evaluated using repeated scans with varying noise and against small variations in the selected regions-of-interest.
resultsThe proposed artifact metric was independent of the underlying image noise and could be reproduced more consistently under slight changes of the region-of-interest within the artifact than the other investigated methods. The coefficient-of-variation was 5.7% on average with varying regions-of-interest in phantom scans and 2.5% in patient scans compared to 9.2% in phantoms scans and 9.9% in patient scans for the next-best performing noise-independent metric. Setup reproducibility was better than 5% and was comparable to the other metrics. The new metric correlated linearly with the artifact strength. The contrast-to-noise ratio, although often used in artifact quantification, was found to be an inadequate metric due to its lack of robustness against minute changes in the position, size, and pixel values of the region-of-interest chosen for calculating the metric and because it showed no correlation with the artifact strength.
conclusionsA new metal artifact metric has been proposed that is robust under changing scan conditions and less sensitive to user-dependent choices of the region-of-interest than other metrics. The new metric is straightforward to calculate and simple to implement in software commonly used for evaluation of medical imaging systems.