ArticleJapanese journal of radiology2024
Unexpected change in hydrogel spacer volume during external-beam radiation therapy.
Article in Japanese journal of radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo reduce the rectal radiation dose during local radiation therapy of prostate cancer, a hydrogel spacer is typically implanted between the prostate and rectum. However, the spacer volume can change during external beam radiation therapy (EBRT). Therefore, we used magnetic resonance imaging (MRI) to determine changes in the spacer volume during EBRT and analyzed the data to identify patient factors influencing this change. MATERIALS AND
methodsA hydrogel spacer was implanted in each enrolled patient diagnosed with prostate cancer (n = 22, age = 69-86 years) for EBRT with a total dose of 70 Gy over 35 fractions. T2-weighted MRI images were acquired before (median = 8 days) and during EBRT, when the radiation dose of 48 Gy (median) was given at 55 days (median) after implantation. MRI images were used to determine the spacer volume as well as the maximum and minimum distances between the prostate and anterior wall of the rectum at the middle height of the prostate. Scatterplots were created to determine whether correlations existed between changes in the spacer volume and these two distances, while uni- and multivariate analyses were conducted to determine if the spacer volume change was influenced by the following patient factors: age, body mass index, estimated glomerular filtration rate, and visceral fat areas at the umbilical and femoral head positions.
resultsThe spacer volume increased in all 22 patients, with the smaller spacer volume before EBRT increasing by a larger amount during EBRT. This increase in the spacer volume was unaffected by other patient factors. However, it correlated with the change in the maximum distance between the prostate and anterior wall of the rectum.
conclusionTo avoid adverse changes in the rectal radiation dose during EBRT, hydrogel spacer volume should be monitored, especially if the pre-EBRT volume is small.