Evidence map›Paper›PMID 38922568›Full record

ArticleJapanese journal of radiology2024

Unexpected change in hydrogel spacer volume during external-beam radiation therapy.

Naoya Ishibashi, Masaharu Hata, Atsushi Fujikawa, Takao Mochizuki, Toshiya Maebayashi, Masahiro Okada

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Naoya IshibashiDepartment of Radiology, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi, Tokyo, 173-8610, Japan. ishibashi.naoya@nihon-u.ac.jp.
Masaharu HataDepartment of Radiation Oncology, Yokohama City University Graduate School of Medicine, 3-9 Fukuura Kanazawa-ku, Yokohama, Kanagawa, 236-0004, Japan.
Atsushi FujikawaDepartment of Urology, Yokosuka City Hospital, 1-3-2 Nagasaka, Yokosuka, Kanagawa, 240-0195, Japan.
Takao MochizukiDepartment of Radiology, Yokosuka City Hospital, 1-3-2 Nagasaka, Yokosuka, Kanagawa, 240-0195, Japan.
Toshiya MaebayashiDepartment of Radiology, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi, Tokyo, 173-8610, Japan.
Masahiro OkadaDepartment of Radiology, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi, Tokyo, 173-8610, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo reduce the rectal radiation dose during local radiation therapy of prostate cancer, a hydrogel spacer is typically implanted between the prostate and rectum. However, the spacer volume can change during external beam radiation therapy (EBRT). Therefore, we used magnetic resonance imaging (MRI) to determine changes in the spacer volume during EBRT and analyzed the data to identify patient factors influencing this change. MATERIALS AND

methodsA hydrogel spacer was implanted in each enrolled patient diagnosed with prostate cancer (n = 22, age = 69-86 years) for EBRT with a total dose of 70 Gy over 35 fractions. T2-weighted MRI images were acquired before (median = 8 days) and during EBRT, when the radiation dose of 48 Gy (median) was given at 55 days (median) after implantation. MRI images were used to determine the spacer volume as well as the maximum and minimum distances between the prostate and anterior wall of the rectum at the middle height of the prostate. Scatterplots were created to determine whether correlations existed between changes in the spacer volume and these two distances, while uni- and multivariate analyses were conducted to determine if the spacer volume change was influenced by the following patient factors: age, body mass index, estimated glomerular filtration rate, and visceral fat areas at the umbilical and femoral head positions.

resultsThe spacer volume increased in all 22 patients, with the smaller spacer volume before EBRT increasing by a larger amount during EBRT. This increase in the spacer volume was unaffected by other patient factors. However, it correlated with the change in the maximum distance between the prostate and anterior wall of the rectum.

conclusionTo avoid adverse changes in the rectal radiation dose during EBRT, hydrogel spacer volume should be monitored, especially if the pre-EBRT volume is small.

Indexed as

Magnetic Resonance ImagingProstatic NeoplasmsRectumAgedAged, 80 and overHumansHydrogelsMaleProstateRadiotherapy DosageHydrogelsExternal-beam radiation therapyHydrogel spacerProstate cancerVolume increase

Identifiers

PMID38922568
PMCPMC11522162

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.