Evidence map›Paper›PMID 38922372›Full record

ArticleEJNMMI physics2024

DosePatch: physics-inspired cropping layout for patch-based Monte Carlo simulations to provide fast and accurate internal dosimetry.

Francesca De Benetti, Julia Brosch-Lenz, Jorge Mario Guerra González, Carlos Uribe, Matthias Eiber, Nassir Navab, Thomas Wendler

Abstract read
In one paragraph

Article in EJNMMI physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Francesca De BenettiChair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany.
Julia Brosch-LenzDepartment of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
Jorge Mario Guerra GonzálezChair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany.
Carlos UribeDepartment of Integrative Oncology, BC Cancer Research Institute, Vancouver, Canada.
Matthias EiberDepartment of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
Nassir NavabChair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany.
Thomas WendlerChair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany. thomas.wendler@med.uni-augsburg.de.ORCID http://orcid.org/0000-0002-0915-0510

Funding

Bayerisches Staatsministerium für Wirtschaft, Infrastruktur, Verkehr und Technologie DIK0127/02Bundesministerium für Bildung und Forschung BiTSPro 13GW0357 ACanadian Institutes of Health Research (CIHR) RN461359 - 46875Natural Sciences and Engineering Research Council (NSERC) RGPIN-2021-02965 (CU)
6 · The paper itself

Abstract

backgroundDosimetry-based personalized therapy was shown to have clinical benefits e.g. in liver selective internal radiation therapy (SIRT). Yet, there is no consensus about its introduction into clinical practice, mainly as Monte Carlo simulations (gold standard for dosimetry) involve massive computation time. We addressed the problem of computation time and tested a patch-based approach for Monte Carlo simulations for internal dosimetry to improve parallelization. We introduce a physics-inspired cropping layout for patch-based MC dosimetry, and compare it to cropping layouts of the literature as well as dosimetry using organ-S-values, and dose kernels, taking whole-body Monte Carlo simulations as ground truth. This was evaluated in five patients receiving Yttrium-90 liver SIRT.

resultsThe patch-based Monte Carlo approach yielded the closest results to the ground truth, making it a valid alternative to the conventional approach. Our physics-inspired cropping layout and mosaicking scheme yielded a voxel-wise error of < 2% compared to whole-body Monte Carlo in soft tissue, while requiring only

conclusionsThis work demonstrates the feasibility and accuracy of physics-inspired cropping layouts for patch-based Monte Carlo simulations.

Indexed as

Dose kernelsDosimetryMonte Carlo simulationsOrgan-S-valuesSIRT

Identifiers

PMID38922372
PMCPMC11208390

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked