Evidence map›Paper›PMID 38921604›Full record

ArticleJournal of imaging2024

Enabling Low-Dose In Vivo Benchtop X-ray Fluorescence Computed Tomography through Deep-Learning-Based Denoising.

Naghmeh Mahmoodian, Mohammad Rezapourian, Asim Abdulsamad Inamdar, Kunal Kumar, Melanie Fachet, Christoph Hoeschen

Abstract read
In one paragraph

Article in Journal of imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Naghmeh MahmoodianChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.ORCID 0000-0003-4963-0495
Mohammad RezapourianChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.ORCID 0000-0002-1810-6511
Asim Abdulsamad InamdarChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.
Kunal KumarChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.ORCID 0000-0001-7585-7285
Melanie FachetChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.ORCID 0000-0002-2530-4057
Christoph HoeschenChair of Medical Systems Technology, Institute for Medical Technology, Faculty of Electrical Engineering and Information Technology, Otto von Guericke University, 39106 Magdeburg, Germany.ORCID 0000-0002-4240-1107

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray Fluorescence Computed Tomography (XFCT) is an emerging non-invasive imaging technique providing high-resolution molecular-level data. However, increased sensitivity with current benchtop X-ray sources comes at the cost of high radiation exposure. Artificial Intelligence (AI), particularly deep learning (DL), has revolutionized medical imaging by delivering high-quality images in the presence of noise. In XFCT, traditional methods rely on complex algorithms for background noise reduction, but AI holds promise in addressing high-dose concerns. We present an optimized Swin-Conv-UNet (SCUNet) model for background noise reduction in X-ray fluorescence (XRF) images at low tracer concentrations. Our method's effectiveness is evaluated against higher-dose images, while various denoising techniques exist for X-ray and computed tomography (CT) techniques, only a few address XFCT. The DL model is trained and assessed using augmented data, focusing on background noise reduction. Image quality is measured using peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), comparing outcomes with 100% X-ray-dose images. Results demonstrate that the proposed algorithm yields high-quality images from low-dose inputs, with maximum PSNR of 39.05 and SSIM of 0.86. The model outperforms block-matching and 3D filtering (BM3D), block-matching and 4D filtering (BM4D), non-local means (NLM), denoising convolutional neural network (DnCNN), and SCUNet in both visual inspection and quantitative analysis, particularly in high-noise scenarios. This indicates the potential of AI, specifically the SCUNet model, in significantly improving XFCT imaging by mitigating the trade-off between sensitivity and radiation exposure.

Indexed as

artificial intelligence (AI)cancerdeep learning (DL)nanoparticlesXFCTX-ray fluorescence (XRF)

Identifiers

PMID38921604
PMCPMC11204716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.