Evidence map›Paper›PMID 38920584›Full record

ArticleBiosensors2024

Concentration of Microparticles/Cells Based on an Ultra-Fast Centrifuge Virtual Tunnel Driven by a Novel Lamb Wave Resonator Array.

Wei Wei, Zhaoxun Wang, Bingnan Wang, Wei Pang, Qingrui Yang, Xuexin Duan

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wei WeiState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.
Zhaoxun WangState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-3360-2812
Bingnan WangState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.
Wei PangState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.
Qingrui YangState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.
Xuexin DuanState Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-7550-3951

Funding

National Key R&D Program of China 2018YFE0118700National Natural Science Foundation of China NSFC No. 62174119
6 · The paper itself

Abstract

The µTAS/LOC, a highly integrated microsystem, consolidates multiple bioanalytical functions within a single chip, enhancing efficiency and precision in bioanalysis and biomedical operations. Microfluidic centrifugation, a key component of LOC devices, enables rapid capture and enrichment of tiny objects in samples, improving sensitivity and accuracy of detection and diagnosis. However, microfluidic systems face challenges due to viscosity dominance and difficulty in vortex formation. Acoustic-based centrifugation, particularly those using surface acoustic waves (SAWs), have shown promise in applications such as particle concentration, separation, and droplet mixing. However, challenges include accurate droplet placement, energy loss from off-axis positioning, and limited energy transfer from low-frequency SAW resonators, restricting centrifugal speed and sample volume. In this work, we introduce a novel ring array composed of eight Lamb wave resonators (LWRs), forming an Ultra-Fast Centrifuge Tunnel (UFCT) in a microfluidic system. The UFCT eliminates secondary vortices, concentrating energy in the main vortex and maximizing acoustic-to-streaming energy conversion. It enables ultra-fast centrifugation with a larger liquid capacity (50 μL), reduced power usage (50 mW) that is one order of magnitude smaller than existing devices, and greater linear speed (62 mm/s), surpassing the limitations of prior methods. We demonstrate successful high-fold enrichment of 2 μm and 10 μm particles and explore the UFCT's potential in tissue engineering by encapsulating cells in a hydrogel-based micro-organ with a ring structure, which is of great significance for building more complex manipulation platforms for particles and cells in a bio-compatible and contactless manner.

Indexed as

CentrifugationAcousticsHumansLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesconcentrationLamb wave resonator arrayultra-fast centrifuge

Identifiers

PMID38920584
PMCPMC11202289

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.