ArticleArchives of toxicology2024
Simultaneous multi-targeted forensic toxicological screening in biological matrices by MRM-IDA-EPI mode.
Article in Archives of toxicology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Exploring the potential of MRM-IDA-EPI method in mass spectrometry for exposomic analysis: a commentary.Archives of toxicology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The toxicologist ascertains drug assumptions in case of paediatric intoxications and death for overdose. The analytical approach consists of initially screening and consequently confirming drug positivity. We developed a toxicological screening method and validated its use comparing the results with a LC-MS/MS analysis. The method identifies 751 drugs and metabolites (704 in positive and 47 in negative mode). Chromatographic separation was achieved eluting mobile phase A (10 mM ammonium formate) and B (0.05% formic acid in methanol) in gradient on Kinetex Phenyl-Hexyl (50 × 4.6 mm, 2.6 μm) with 0.7 mL/min flow rate for 11 min. Multiple Reaction Monitoring (MRM) was adopted as survey scan and, after an Information-Dependent Analysis (IDA) (threshold of 30,000 for positive and 1000 cps for negative mode), the Enhanced Product Ion (scan range: 50-700 amu) was triggered. The MS/MS spectrum generated was compared with one of the libraries for identification. Data processing was optimised through creation of rules. Sample preparation, mainly consisting of deproteinization and enzymatic hydrolysis, was set up for different matrices (blood, urine, vitreous humor, synovial fluid, cadaveric tissues and larvae). Cut-off for most analytes resulted in the lowest concentration tested. When the results from the screening and LC-MS/MS analysis were compared, an optimal percentage of agreement (100%) was assessed for all matrices. Method applicability was evaluated on real paediatric intoxications and forensic cases. In conclusion, we proposed a multi-targeted, fast, sensitive and specific MRM-IDA-EPI screening having an extensive use in different toxicological fields.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.