Evidence map›Paper›PMID 38916826›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2025

Aortic valve area index values of Trifecta implants correlate with energy loss and increased valve stress.

Toru Tsukada, Yasuyuki Suzuki, Bryan J Mathis, Kimi Sato, Takeshi Kawamata, Akito Imai, Tomomi Nakajima, Yuichiro Kaminishi, Hideyuki Kato, Hiroaki Sakamoto and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Toru TsukadaDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Yasuyuki SuzukiDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan. Ysuzuki@md.tsukuba.ac.jp.ORCID http://orcid.org/0000-0001-8073-0633
Bryan J MathisDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Kimi SatoDepartment of Cardiology, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Takeshi KawamataDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Akito ImaiDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Tomomi NakajimaDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Yuichiro KaminishiDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Hideyuki KatoDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Hiroaki SakamotoDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Yuji HiramatsuDepartment of Cardiovascular Surgery, University of Tsukuba Institute of Medicine, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs - 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.

Indexed as

Aortic ValveBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationAgedEchocardiography, StressFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedProsthesis Design4D flow MRIAortic valve replacementBioprosthesesEchocardiographyExercise test

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.