Evidence map›Paper›PMID 38915972›Full record

ArticleCureus2024

Surgical and Patient-Reported Outcomes After Mastectomy and Implant-Based Prepectoral Reconstruction Using TIGR® Synthetic Mesh.

Shiveta Razdan, Goran A Ahmed, Gayatri Vishwakarma, Chwanrow Baban, Alexandra Tenovici

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Early Outcomes Using TIGR Mesh in Direct-to-Implant Breast Reconstruction.Plastic and reconstructive surgery. Global open · 2025
    Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shiveta RazdanBreast Surgery, Amrita Institute of Medical Science and Research, Faridabad, IND.
Goran A AhmedBreast Surgery, Frimley Health NHS Foundation Trust, Surrey, GBR.
Gayatri VishwakarmaBiostatistics, Zydus Research Centre, Ahmedabad, IND.
Chwanrow BabanBreast Surgery, University Hospital Limerick, Limerick, IRL.
Alexandra TenoviciBreast Surgery, Frimley Health NHS Foundation Trust, Surrey, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Single-stage direct-to-implant (DTI) breast reconstruction after mastectomy has gained popularity over the last decade, thanks to the wide use of biological matrices and synthetic meshes. Despite their high cost, there is no evidence of superior outcome from the biological matrices compared to the synthetic meshes. In this study, we aimed to evaluate our experience with TIGR, a synthetic, long-term absorbable mesh, in mastectomy and immediate breast reconstruction (MIBR) with a focus on patient-reported outcomes (PROMs). Methods This was a single-trust prospective quality improvement study conducted between 2017 and 2019. The main objectives were complication rates including infection, implant loss, and other surgical complications in patients undergoing TIGR mesh-assisted MIBR in the prepectoral plane for either cancer or risk reduction. PROMs were measured using the validated European Organisation for Research and Treatment of Cancer (EORTC) breast questionnaire module. Clinical evaluations were conducted at one week, three weeks, and 12 months postoperatively. All patients provided written consent, and the audit was registered with the Quality Improvement Department of the organization. Results One hundred and twelve meshes were used in 93 patients with a mean age of 49 (24-75) years and a body mass index (BMI) of 23.4 (19.1-29.6). During the follow-up period, complications occurred in 26 patients (28%), including infection in four (4.3%), complete skin flap necrosis in one (1%), partial flap necrosis in three (3.2%), and implant loss in four (4.3%) patients. PROM data from 41 individuals indicated a moderate overall quality of life (82.7%), with high functional domain scores with relatively lower emotional functioning scores. Symptom domains generally scored poorly except for body image and sexual functioning. Conclusion Mastectomy and immediate prepectoral breast reconstruction using TIGR mesh is safe with low major complication rates. It is associated with high functional and quality of life scores but low scores in symptom domains which could be multifactorial. However, limitations due to study type and follow-up duration suggest caution in generalizing findings.

Indexed as

acellular dermal matrixbreast cancerbreast reconstructionmibrprepectoral reconstructionquality of lifesynthetic meshtigr matrix

Identifiers

PMID38915972
PMCPMC11195315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.