Evidence map›Paper›PMID 38915476›Full record

ArticleCase reports in cardiology2024

Successful Retrieval of Rota Burr After Driveshaft Fracture.

Tsuyoshi Kobayashi, Takeo Horikoshi, Toru Yoshizaki, Akira Sato

Abstract readCase Reports
In one paragraph

Article in Case reports in cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Management of Lost Atherectomy Devices in the Coronary Arteries.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tsuyoshi KobayashiDepartment of Cardiology University of Yamanashi, 1110, Shimokato, Chuo, Yamanashi 409-3898, Japan.ORCID https://orcid.org/0009-0000-9713-7393
Takeo HorikoshiDepartment of Cardiology University of Yamanashi, 1110, Shimokato, Chuo, Yamanashi 409-3898, Japan.
Toru YoshizakiDepartment of Cardiology University of Yamanashi, 1110, Shimokato, Chuo, Yamanashi 409-3898, Japan.
Akira SatoDepartment of Cardiology University of Yamanashi, 1110, Shimokato, Chuo, Yamanashi 409-3898, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rotational atherectomy is an effective procedure for heavily calcified lesions and those that cannot be crossed using conventional percutaneous coronary intervention (PCI) devices. Here, we report a rare case of intracoronary burr entrapment in the coronary artery due to burr disconnection from the driveshaft. A 67-year-old man undergoing hemodialysis for nephrosclerosis presented with exertional chest discomfort. Coronary angiography revealed stenotic lesions in the right coronary artery, and PCI was performed using a Rotawire Floppy. During the procedure, the disconnected burr was successfully removed without surgery using the child-in-mother technique with a guide extension catheter. Notably, the patient remained hemodynamically stable throughout the procedure and his recovery was uncomplicated. He was discharged on the second postprocedural day. At the 6-month follow-up, the patient remained asymptomatic with no evidence of myocardial ischemia. This report informs clinicians of the possibility of burr disconnection and the non-surgical intervention used for its removal.

Identifiers

PMID38915476
PMCPMC11196185

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.