Evidence map›Paper›PMID 38914709›Full record

ArticleScientific reports2024

Comparison of tibial fracture plate length, placement, and fibular integrity effects on plate integrity through finite element analysis.

Byung Hoon Lee, Yeokyung Kang, Sung Ha Cho, Myung Moon, Jae Ang Sim, Jungsung Kim

Erratum issuedAbstract readComparative Study
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Byung Hoon LeeDepartment of Orthopaedic Surgery, Gachon University College of Medicine, 21, Namdong-Daero 774 Beon-Gil, Namdong-Gu, Incheon, Republic of Korea.
Yeokyung KangCentral Research and Development Center, Corentec Company Ltd., 33-2, Banpo-Daero 20-Gil, Seocho-Gu, Seoul, Republic of Korea.
Sung Ha ChoDepartment of Orthopaedic Surgery, Gachon University College of Medicine, 21, Namdong-Daero 774 Beon-Gil, Namdong-Gu, Incheon, Republic of Korea.
Myung MoonGachon University College of Medicine, Incheon, Republic of Korea.
Jae Ang SimDepartment of Orthopaedic Surgery, Gachon University College of Medicine, 21, Namdong-Daero 774 Beon-Gil, Namdong-Gu, Incheon, Republic of Korea. sim_ja@gilhospital.com.
Jungsung KimCentral Research and Development Center, Corentec Company Ltd., 33-2, Banpo-Daero 20-Gil, Seocho-Gu, Seoul, Republic of Korea. jskim@corentec.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Minimally invasive plate osteosynthesis is the most commonly used minimally invasive surgery technique for tibial fractures, possibly involving single or dual plate methods. Herein, we performed a finite element analysis to investigate plate strength according to the plate type, length, and presence of a fibula by constructing a three-dimensional tibia model. A thickness of 20 mm was cut 50 mm distal from the lateral plateau, and the ligaments were created. Plates were modeled with lengths of 150, 200, and 250 mm and mounted to the tibia. Screws were arranged to avoid overlapping in the dual plating. The von-Mises stress applied to the plates was measured by applying a load of 1 body weight. Dual plates showed the least stress with low displacement, followed by medial and lateral plates. As the plate length increased, the average stress gradually decreased, increasing plate safety. The difference in the influence of the fibula depending on the presence of proximal fibula osteotomy showed that the average stress increased by 35% following proximal fibula osteotomy in the D1(Plate type: Dual plate, Medial plate length: 150 mm, Lateral plate length: 200 mm, Non Proximal fibula osteotomy) and D1P(Plate type: Dual plate, Medial plate length: 150 mm, Lateral plate length: 200 mm, Proximal fibula osteotomy) models, confirming the necessity of the fibula model. There is no consensus guideline for treatment of this kind of fracture case. A single fracture plate can decrease the risk of skin damage, ligament damage, and wound infection, but because of its design, it cannot provide sufficient stability and satisfactory reduction of the condylar fragment, especially in cases of comminution or coronal fracture. So, these results will help clinicians make an informed choice on which plate to use in patients with tibial fractures.

Indexed as

Bone PlatesFibulaFinite Element AnalysisFracture Fixation, InternalTibial FracturesBiomechanical PhenomenaHumansMinimally Invasive Surgical ProceduresStress, MechanicalTibia

Identifiers

PMID38914709
PMCPMC11196683

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked