Evidence map›Paper›PMID 38914129›Full record

ArticleUltraschall in der Medizin (Stuttgart, Germany : 1980)2025

Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review.

Sophie Dassen, Loes Monen, Guid Oei, Massimo Mischi, Judith van Laar

Registry-linked trialAbstract readScoping Review
In one paragraph

Article in Ultraschall in der Medizin (Stuttgart, Germany : 1980), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07422181 (PlaCEUS), which is not on this map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07422181 narecruitingnot on this map

PlaCEUS: Feasibility Study of Contrast-enhanced Ultrasound to Visualize Maternal Uterine Spiral Arteries Postpartum.

TypeinterventionalSponsorMaxima Medical CenterRan2025 to 2026Enrolled5ConditionsSpiral Arteries, Uterine Artery Hemodynamics, Contrast Enhanced Ultrasound, Doppler ParametersArmsSonoVue (sulphur hexafluoride microbubbles)
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sophie DassenObstetrics and Gynecology, Maxima Medical Centre, Veldhoven, Netherlands.
Loes MonenObstetrics and Gynecology, Maxima Medical Centre, Veldhoven, Netherlands.
Guid OeiFundamental Perinatology, Technische Universiteit Eindhoven, Eindhoven, Netherlands.
Massimo MischiElectrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Judith van LaarObstetrics and Gynecology, Maxima Medical Centre, Veldhoven, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date.A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes.A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described.Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.

Indexed as

Contrast MediaImage EnhancementMicrobubblesPlacental InsufficiencyUltrasonography, PrenatalFemaleHumansInfant, NewbornPlacentaPregnancyPregnancy OutcomeContrast Media

Identifiers

PMID38914129
PMCPMC12143933

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.