Evidence map›Paper›PMID 38913866›Full record

ArticleDento maxillo facial radiology2024

Assessment of cone-beam CT technical image quality indicators and radiation dose for optimal STL model used in visual surgical planning.

Juha Koivisto, Jan Wolff, Ruben Pauwels, Touko Kaasalainen, Anni Suomalainen, Patricia Stoor, Jani Horelli, Juho Suojanen

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Juha KoivistoDepartment of Physics, University of Helsinki, 00560 Helsinki, Finland.ORCID 0000-0003-3957-8304
Jan WolffDepartment of Dentistry and Oral Health, Section of Oral and Maxillofacial Surgery and Oral Pathology, Aarhus University, DK-8000 Aarhus C, Denmark.
Ruben PauwelsDepartment of Dentistry and Oral Health, Aarhus University, DK-8000 Aarhus C, Denmark.
Touko KaasalainenHUS Diagnostic Center, Radiology, University of Helsinki, Helsinki, P.O. BOX 224, FI-00029, Finland.
Anni SuomalainenHUS Diagnostic Center, Radiology, University of Helsinki, Helsinki, P.O. BOX 224, FI-00029, Finland.
Patricia StoorHelsinki University Hospital, Helsinki, P.O. Box 63 00014, Finland.
Jani HorelliPlanmeca Oy, 00880 Helsinki, Finland.
Juho SuojanenHelsinki University Hospital, Helsinki, P.O. Box 63 00014, Finland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe aim of this study was to identify cone-beam computed tomography (CBCT) protocols that offer an optimal balance between effective dose (ED) and 3D model for orthognathic virtual surgery planning, using CT as a reference, and to assess whether such protocols can be defined based on technical image quality metrics.

methodsEleven CBCT (VISO G7, Planmeca Oy, Helsinki, Finland) scan protocols were selected out of 32 candidate protocols, based on ED and technical image quality measurements. Next, an anthropomorphic RANDO SK150 phantom was scanned using these 11 CBCT protocols and 2 CT scanners for bone quantity assessments. The resulting DICOM (Digital Imaging and Communications in Medicine) files were converted into Standard Tessellation Language (STL) models that were used for bone volume and area measurements in the predefined orbital region to assess the validity of each CBCT protocol for virtual surgical planning.

resultsThe highest CBCT bone volume and area of the STL models were obtained using normal dose protocol (F2) and ultra-low dose protocol (J13), which resulted in 48% and 96% of the mean STL bone volume and 48% and 95% of the bone area measured on CT scanners, respectively.

conclusionsThe normal dose CBCT protocol "F2" offered optimal bone area and volume balance for STL. The optimal CBCT protocol can be defined using contrast-to-noise ratio and modulation transfer function values that were similar to those of the reference CT scanners'. CBCT scanners with selected protocols can offer a viable alternative to CT scanners for acquiring STL models for virtual surgical planning at a lower effective dose.

Indexed as

Cone-Beam Computed TomographyPhantoms, ImagingRadiation DosageHumansImaging, Three-DimensionalPatient Care Planning3-dimensionalcone-beam computed tomographyorbitStandard Tessellation Language

Identifiers

PMID38913866
PMCPMC11358642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked