Evidence map›Paper›PMID 38913189›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2024

Voxel-based tumor dose correlates to complete pathologic necrosis after transarterial radioembolization for hepatocellular carcinoma.

Kurt T Pianka, Mark Barahman, Jeet Minocha, Jonas W Redmond, Gabriel T Schnickel, Steven C Rose, Kathryn J Fowler, Zachary T Berman

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kurt T PiankaSchool of Medicine, University of California San Diego, La Jolla, CA, USA.
Mark BarahmanDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA.
Jeet MinochaDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA.
Jonas W RedmondDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA.
Gabriel T SchnickelDepartment of Surgery, University of California San Diego, La Jolla, CA, 92103, USA.
Steven C RoseDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA.
Kathryn J FowlerDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA.
Zachary T BermanDepartment of Radiology, University of California San Diego, 200 West Arbor Drive, Mail Code 8756, San Diego, CA, USA. zberman@health.ucsd.edu.ORCID 0000-0002-8651-9772

Funding

Traning Clinical Scientists in Radiological ImagingT32EB005970 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Eric Y Chang, Rebecca Ann Rakow-Penner · 2007 to 2026
$3.2M
NIBIB NIH HHS T32 EB005970
6 · The paper itself

Abstract

purposeThe transarterial radioembolization (TARE) dose is traditionally calculated using the single-compartment Medical Internal Radiation Dose (MIRD) formula. This study utilized voxel-based dosimetry to correlate tumor dose with explant pathology in order to identify dose thresholds that predicted response.

methodsAll patients with HCC treated with TARE using yttrium-90 [

resultsForty-one patients were included. Twenty-six (63%) met criteria for complete response. Dose to 95% (D95), 70% (D70), and 50% (D50) of the tumor volume were associated with likelihood of complete response by logistic regression (all p < 0.05). For lesions with complete response versus without, the median D95 was 813 versus 232 Gy, D70 was 1052 versus 315 Gy, and D50 was 1181 versus 369 Gy (all p < 0.01). A D95 > 719 Gy had the highest accuracy at 68% (58% sensitivity, 87% specificity) for predicting complete response. Median percent of tumor volume receiving at least 100 Gy (V100), 200 Gy (V200), 300 Gy (V300), and 400 Gy (V400) also differed by pathologic response: the median V100, V200, V300, and V400 was 100% versus 99%, 100% versus 97%, 100% versus 74%, and 100% versus 43% in the complete response versus non-complete response groups, respectively (all p < 0.05).

conclusionVoxel-based dosimetry was well-correlated with explant pathology. The D95 threshold had the highest accuracy, suggesting the D95 may be a relevant target for multi-compartment dosimetry.

Indexed as

Carcinoma, HepatocellularEmbolization, TherapeuticLiver NeoplasmsNecrosisYttrium RadioisotopesAdultAgedFemaleHumansMaleMiddle AgedRadiotherapy DosageTreatment OutcomeYttrium-90Yttrium RadioisotopesHepatocellular carcinomaMulti-compartment dosimetryTransarterial radioembolizationVoxel-based dosimetry

Identifiers

PMID38913189
PMCPMC13012810

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.