Fast and accurate newborn heart rate monitoring at birth: A systematic review.

Vishal S Kapadia, Mandira D Kawakami, Marya L Strand, Cameron Paul Hurst, Angela Spencer, Georg M Schmölzer, Yacov Rabi, Jonathan Wyllie, Gary Weiner, Helen G Liley and 2 more

Abstract readReview
In one paragraph

Review in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Observational
  2. Article
  3. Observational
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Vishal S KapadiaUniversity of Texas Southwestern Medical Center, Dallas, TX, United States.
Mandira D KawakamiFederal University of Sao Paulo, Sao Paulo, Brazil.
Marya L StrandAkron Children's Hospital, Akron, OH, United States.
Cameron Paul HurstCharles Darwin University, Brisbane, Queensland Australia.
Angela SpencerSaint Louis University School of Medicine, St. Louis, MO, United States.
Georg M SchmölzerUniversity of Alberta, Edmonton, Alberta, Canada.
Yacov RabiUniversity of Calgary, Calgary, Alberta, Canada.
Jonathan WyllieJames Cook University Hospital, Middlesbrough, United Kingdom.
Gary WeinerUniversity of Michigan, Ann Arbor, MI, United States.
Helen G LileyUniversity of Queensland, South Brisbane, Queensland, Australia.
Myra H WyckoffUniversity of Texas Southwestern Medical Center, Dallas, TX, United States.
International Liaison Committee on Resuscitation Neonatal Life Support Task Force

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. Methods: A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence. Results: Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes. Limitations: Certainty of evidence was low or very low for most comparisons. Conclusion: If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.

Indexed as

AuscultationBradycardiaDigital stethoscopeDoppler ultrasoundDry electrode ECGElectrocardiogramHeart RateILCORMeta-analysisNewbornNRPPalpationPulse oximeterResuscitationSystematic review

Identifiers

PMID38912532
PMCPMC11190559

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.