Evidence map›Paper›PMID 38910981›Full record

ArticleJournal of orthopaedic case reports2024

Precise Calibration of Femoral Component Rotation Using the Posterior Condylar Axis as a Reference during Image-free Robot-assisted Total Knee Arthroplasty: A Technical Note.

Apurve Parameswaran, Jakkidi N Reddy, Vinay K Ponnala, Sunil Apsingi, Krishna K Eachempati

Abstract read
In one paragraph

Article in Journal of orthopaedic case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Apurve ParameswaranDepartment of Orthopaedic Surgery, Medicover Hospitals, Hyderabad, Telangana, India.
Jakkidi N ReddyDepartment of Orthopaedic Surgery, Medicover Hospitals, Hyderabad, Telangana, India.
Vinay K PonnalaDepartment of Orthopaedic Surgery, Medicover Hospitals, Hyderabad, Telangana, India.
Sunil ApsingiDepartment of Orthopaedic Surgery, Medicover Hospitals, Hyderabad, Telangana, India.
Krishna K EachempatiDepartment of Orthopaedic Surgery, Medicover Hospitals, Hyderabad, Telangana, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The use of image-free robotic systems for total knee arthroplasty (TKA) is gaining popularity. Although the surgical transepicondylar axis (sTEA) is considered the optimal femoral rotational reference during TKA, it is difficult to define intra-operatively. Conventional and image-free robot-assisted TKA (RA-TKA) therefore rely on the use of Whiteside's axis (WSA) or the posterior condylar axis (PCA) as surrogate references. The PCA is considered to be associated with less variability than the WSA. The authors present a simple technique to permit calibration of femoral component rotation (FCR) using the PCA as a reference for image-free robotic systems that do not permit this option. Technique: The image-free robotic systems used by the authors (Navio and CORI, Smith and Nephew, Memphis, TN, USA) permit calibration of FCR only when the perpendicular to WSA is used as a reference. When the PCA is selected as a reference, a fixed 3° of external rotation is set by the robot. The technique proposed by the authors involves the use of the former setting, followed by internal rotation of the perpendicular to the WSA to co-align it with the PCA. The planning menu subsequently permits virtual surgical planning using the PCA as the femoral rotational reference and permits adjustments in rotational positioning of the femoral component while displaying the effect of rotation on bony resection and vice versa in real time. In addition, coaligning the perpendicular to the anatomic trans-epicondylar axis (aTEA) displays the internal rotation of the PCA with respect to the aTEA. This information can be used for setting rotational boundaries with respect to the PCA while using various alternate alignment strategies, like functional alignment, since the relation between the aTEA and sTEA is less likely to be affected by dyplasia and wear when compared with the PCA or WSA. Conclusion: This simple technique permits optimally calibrated rotational positioning of the femoral component during image-free RA-TKA, using the PCA as a reference. It can be applied for optimizing surgery in knees with altered or outlier anatomy, as well as routinely, especially when alternate alignment strategies are used.

Indexed as

Femoral component rotationimage-free roboticsposterior condylar axisrobot-assisted total knee arthroplastytrans-epicondylar axis

Identifiers

PMID38910981
PMCPMC11189082

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.