Evidence map›Paper›PMID 38910200›Full record

ArticleInternational ophthalmology2024

A comparison of iCare and Goldmann applanation tonometry measurements during the COVID-19 pandemic: a retrospective study.

Shreya Swaminathan, Amber M Kisielewski, M Hossein Nowroozzadeh, Shahin Hallaj, Daniel Lee, Natasha N Kolomeyer, Jonathan S Myers, Reza Razeghinejad

Abstract readComparative Study
In one paragraph

Article in International ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shreya SwaminathanSidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, 19107, USA. shreya.swaminathan@students.jefferson.edu.
Amber M KisielewskiGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.
M Hossein NowroozzadehDepartment of Ophthalmology, Shiraz University of Medical Sciences, Shiraz, Iran.
Shahin HallajGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.
Daniel LeeGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.
Natasha N KolomeyerGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.
Jonathan S MyersGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.
Reza RazeghinejadGlaucoma Service, Wills Eye Hospital, 840 Walnut St, Philadelphia, PA, 19107, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate factors associated with differences in intraocular pressure (IOP) readings between iCare and Goldmann applanation tonometry (GAT) in established glaucoma patients.

methodsThis retrospective comparative study included clinical data of 350 eyes from 350 established glaucoma patients who had iCare and GAT IOP measured by an ophthalmic technician and a glaucoma specialist, respectively. The main outcome measure was the difference in IOP measurements of the right eyes with iCare and GAT.

resultsThe intraclass correlation coefficient (ICC) between GAT and iCare was 0.90. The mean IOP difference between tonometers was - 0.18 ± 2.89 mmHg. Bland-Altman plots indicated a 95% limit of agreement of - 5.8 to 5.5 mmHg. Central corneal thickness (CCT) and age were significantly correlated with the difference in IOPs of the iCare and GAT. GAT-IOP and age were significantly associated with the absolute difference in measured IOP of the two tonometers. The difference in measurements was not significantly associated with prior glaucoma surgery, average global index of optical coherence tomography, axial length, technician years of experience and certification, and IOP range.

conclusionAlthough there is good agreement between the iCare and GAT mean values, these devices are not interchangeable in glaucoma patients due to the wide range of the limit of agreement.

Indexed as

COVID-19GlaucomaIntraocular PressureTonometry, OcularAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedPandemicsReproducibility of ResultsRetrospective StudiesSARS-CoV-2GlaucomaGoldmann applanation tonometryiCareIntraocular pressure

Identifiers

PMID38910200
PMCPMC11194190

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.