Evidence map›Paper›PMID 38904797›Full record

ArticleAnalytical and bioanalytical chemistry2024

HPLC-MS/MS-based quantification of human monoclonal antibodies targeting SARS-CoV-2 in the presence of endogenous SARS-CoV-2 antibodies in human serum.

Alexander Schäfer, Peter Sagelsdorff, Björn Hock, Prakash Bhuyan, Norman Moullan, Christoph Siethoff

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alexander SchäferSwiss BioQuant AG, Reinach, Switzerland. alexander.schaefer@swissbioquant.com.
Peter SagelsdorffSwiss BioQuant AG, Reinach, Switzerland.
Björn HockLavaux Biotech Consulting, Yens, Switzerland.
Prakash BhuyanAerium Therapeutics, Boston, MA, USA.
Norman MoullanAerium Therapeutics, Epalinges, Switzerland.
Christoph SiethoffSwiss BioQuant AG, Reinach, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Antibodies for treatment and prophylaxis against SARS-CoV-2 are needed particularly for immunocompromised individuals, who cannot adequately benefit from vaccination. To address this need, Aerium Therapeutics is developing antibodies targeting the SARS-CoV-2 spike protein. A bioanalytical method to quantify fully human monoclonal antibodies in a population with widely varying anti-spike antibody titers is required to investigate the pharmacokinetics of these antibodies in clinical trials. To eliminate interference from endogenous anti-spike protein antibodies, an HPLC-MS/MS assay was developed to quantify the investigational monoclonal antibodies (AER001 and AER002) by targeting signature peptides spanning the monoclonal antibodies' CDR regions. By optimizing and comparing affinity capture and ammonium sulphate precipitation, it was demonstrated that both procedures allowed accurate and precise quantification of AER001 and AER002 in human serum with comparable sensitivity. Ammonium sulphate precipitation outperformed immunocapture due to its simplicity and speed at lower cost and a full bioanalytical method validation was performed in human serum. The assay was also validated for human nasal lining fluid extract with a 50-fold lower limit of quantification and was shown to deliver similar sensitivity to previously published affinity capture HPLC-MS/MS assays. Finally, the CDR-derived signature peptides were also generated by tryptic digestion of blank serum in some individuals, an important caveat for HPLC-MS/MS strategies targeting human monoclonal antibodies. In summary, the presented results show that ammonium sulphate precipitation and HPLC-MS/MS allow accurate and precise quantification of monoclonals in clinical studies. The developed methods demonstrate that HPLC-MS/MS can reliably quantify human monoclonal antibodies even when endogenous antibodies with overlapping specificities are present and are crucial for the clinical testing of two investigational COVID-19 monoclonals.

Indexed as

Antibodies, MonoclonalAntibodies, ViralCOVID-19Chromatography, High Pressure LiquidHumansLimit of DetectionLiquid Chromatography-Mass SpectrometrySARS-CoV-2Spike Glycoprotein, CoronavirusTandem Mass SpectrometryAntibodies, MonoclonalAntibodies, ViralSpike Glycoprotein, Coronavirusspike protein, SARS-CoV-2Affinity captureBioanalysisCOVID-19HPLC–MS/MSMonoclonal antibodyTargeted protein quantification

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.