Evidence map›Paper›PMID 38904679›Full record

SynthesisWorld journal of urology2024

Can CT or MRI volumetry substitute scintigraphy in living kidney donor evaluation? A systematic review.

Alicia López-Abad, Thomas Prudhomme, Alessio Pecoraro, Romain Boissier, Muhammet Irfan Dönmez, Alberto Piana, Beatriz Bañuelos Marco, Mario Belmonte, Sergio Serni, Riccardo Campi and 1 more

Abstract readSystematic Review
In one paragraph

Synthesis in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Alicia López-Abad *Department of Urology, Virgen de La Arrixaca University Hospital, Murcia, Spain.
Thomas Prudhomme *Department of Urology, Kidney Transplantation and Andrology, Toulouse Rangueil University Hospital, Toulouse, France.
Alessio PecoraroUnit of Urological Robotic Surgery and Renal Transplantation, Careggi Hospital, University of Florence, Viale San Luca, 50134, Florence, Italy.
Romain BoissierDepartment of Urology and Renal Transplantation, Aix-Marseille University, La Conception University Hospital, Marseille, France.
Muhammet Irfan DönmezDepartment of Urology, Istanbul University Istanbul Faculty of Medicine, Istanbul, Turkey.
Alberto PianaDepartment of Oncology, Division of Urology, University of Turin, Turin, Italy.
Beatriz Bañuelos MarcoDepartment of Urology, Kidney Transplantation and Reconstructive Urology, Hospital Universitario Clinico San Carlos, Madrid, Spain.
Mario BelmonteUnit of Urological Robotic Surgery and Renal Transplantation, Careggi Hospital, University of Florence, Viale San Luca, 50134, Florence, Italy.
Sergio SerniUnit of Urological Robotic Surgery and Renal Transplantation, Careggi Hospital, University of Florence, Viale San Luca, 50134, Florence, Italy.
Riccardo Campi *Unit of Urological Robotic Surgery and Renal Transplantation, Careggi Hospital, University of Florence, Viale San Luca, 50134, Florence, Italy. riccardo.campi@gmail.com.ORCID http://orcid.org/0000-0001-5237-0888
Angelo Territo *Department of Urology, Fundació Puigvert, Autonoma University of Barcelona, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCurrent potential living kidney donor's assessment includes functional and anatomical evaluation. Scintigraphy is recommended in some cases and some centers include this test in the donor's protocol. Recent studies advocate for the avoidance of this test as CT or MRI volumetry showed to accurately assess donor's renal function.

objectiveTo summarize scientific evidence on image tests for pre-donation and/or post-nephrectomy renal function evaluation. EVIDENCE ACQUISITION: This review followed the guidelines set by the European Association of Urology and adhered to PRISMA 2020 recommendations. The protocol was registered in PROSPERO on 10th December 2022 (ID: CRD42022379273). EVIDENCE SYNTHESIS: Twenty-one studies met the inclusion criteria after thorough screening and eligibility assessment. According to QUADAS-2, patient selection and flow/timing domains showed a predominant low risk of bias. The correlation between split renal function (SRF) using CT and scintigraphy varied from weak (r = 0.21) to remarkably strong (r = 0.949). Bland-Altman agreement demonstrated moderate to excellent results, with mean differences ranging from -0.06% to 1.76%. The correlation between split renal volume (CT) and estimated glomerular filtration rate (eGFR) at 6 months or 1 year after nephrectomy showed a moderate correlation, with coefficients ranging from 0.708 to 0.83. The correlation between SRF (MRI) and renal scintigraphy reported a moderate correlation, with correlation coefficients of 0.58 and 0.84. MRI and scintigraphy displayed a good agreement, with a 66% agreement observed and mean differences of ± 0.3%.

conclusionsDespite study heterogeneity, MRI or CT-based renal volumetry appears promising compared to scintigraphy, with favorable correlations and agreement.

Indexed as

KidneyKidney TransplantationLiving DonorsMagnetic Resonance ImagingNephrectomyRadionuclide ImagingTomography, X-Ray ComputedHumansKidney Function TestsTissue and Organ HarvestingComputed tomographyKidney donorLiving kidney transplantationMagnetic resonance imagingNephrectomyRenal functionScintigraphy

Identifiers

PMID38904679
PMCPMC11192666

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.